EasyManua.ls Logo

Soleus Air R-410A - User Manual

Soleus Air R-410A
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2010 Soleus Air International
14,000 BTU Portable Air Conditioner
14,200 BTU Heat Pump
LX-140 / LX-140BL R-410A
Operating Instructions
Model No. LX-140
®
3092402
www.nitropdf.com
Service Questions: Contact Soleus Air at (888) 876-5387
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
Service Questions: Contact Soleus Air at (888) 876-5387
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
Question and Answer IconNeed help?

Do you have a question about the Soleus Air R-410A and is the answer not in the manual?

Summary

Important Safety Instructions

Specifications

LCDI Power Cord and Plug

Dual Hose Window Kit Installation

Venting Kit Installation Steps

Detailed instructions for installing the venting kit for dual hose operation.

Window Kit Assembly

Single Hose Installation

Single Hose Exhaust and Window Kit

Instructions for using a single hose and window kit for spot cooling.

Control Panel and Display

Operating the Unit

Control Panel Operation

Using buttons on the control panel for Power, Mode, Fan Speed, Temperature, and Timer.

Air Conditioner Mode Operation

Steps to operate the unit in Air Conditioner mode.

Dehumidifier Mode Operation

Steps to operate the unit in Dehumidifier mode, including notes.

Heating Mode Operation

Steps to operate the unit in Heating mode.

Auto Mode Operation

How the unit automatically selects modes based on room temperature.

Emergency Condensate Handling

Emptying the Condensate Tank

Step-by-step process to drain the emergency condensate holding tank.

Remote Control Operation

Remote Power and Mode Control

Using the POWER and MODE buttons on the remote for unit control.

Remote Fan Speed and Temperature

Adjusting fan speed and temperature using the remote control buttons.

Maintenance Procedures

Air Filter Care

Instructions for cleaning or replacing the air filter to maintain airflow.

Overview

This document describes the Soleus Air LX-140/LX-140BL R-410A Portable Air Conditioner with Heat Pump, offering detailed operating instructions, technical specifications, and maintenance guidelines.

Function Description

The Soleus Air LX-140/LX-140BL is a versatile portable air conditioner and heat pump designed to provide comfort in various environments. It functions as an air conditioner, heater, dehumidifier, and fan, making it suitable for year-round use. In air conditioning and dehumidifier modes, the unit draws in fresh outdoor air and exhausts hot air. In heat mode, it exhausts cool air. When operating in fan mode, no outdoor air exchange takes place, and the venting kit is not required. The unit is equipped with WAVEFLO® technology, which enables the louvers to oscillate back and forth and up and down, spreading air throughout the room more effectively. For quick spot cooling, a single hose window kit installation is available, while a dual hose setup is recommended for efficiently cooling larger areas. The unit features an LCDI (Leakage Current Detection and Interruption) power cord and plug, a safety feature designed to reduce the risk of fire by disconnecting the power source if current leakage is detected.

Important Technical Specifications

  • Model: LX-140 / LX-140BL R-410A
  • Cooling Capacity: 14,000 BTU/H
  • Heating Capacity: 14,200 BTU/H
  • Dehumidifying Capacity: 60 pts/Day
  • Power (Cooling): 1390W
  • Power (Heating): 1180W
  • Air Flow Volume: 225 CFM
  • Power Source: 115 V~60 HZ, 12.5 AMP (Cooling) / 11 AMP (Heating)
  • Sound Pressure Level: <46 dB(A)
  • Net Weight: 83 Lbs
  • Operating Temperature (Cooling): 60.8°F - 107.6°F
  • Operating Temperature (Heating): 23°F - 89.6°F
  • Dimensions (Assembled): 17.5" W × 32.75" H × 19" D
  • Refrigerant: R-410A
  • Window Kit Length: Up to 8 ft. (4 sliding panels: 1 dual hose panel, 1 single hose panel, 2 extension panels)
  • Condensate Tank Capacity: Approximately 1.5 Liters (emergency condensate tank)

Usage Features

The unit can be operated via a control panel on the unit itself or a remote control.

  • Power On and Off: Press the POWER button on the control panel or remote control.
  • Mode Selection: Cycle through Auto, Air Conditioner, Dehumidifier, Fan only, and Heater modes using the MODE button.
  • Fan Speed Control: Select High, Medium, Low, or Auto fan speeds using the FAN SPEED button. Auto speed is available in heating and cooling modes.
  • Temperature Setting: Adjust desired room temperature (61°F - 88°F or 16°C - 31°C) in cooling or heating modes using the up/down arrow keys. The °F/°C button on the control panel allows switching between Fahrenheit and Celsius.
  • Timer Function: Program the unit to automatically turn on (TIMER ON) or turn off (TIMER OFF) at a desired time. The timer remembers previous settings for mode, temperature, fan speed, and oscillation.
  • Sleep Mode: (Remote control only) Available in Air Conditioner and Heating modes. In AC mode, temperature gradually increases by 2°F over 6 hours. In Heating mode, temperature gradually decreases by 2°F over 6 hours. Fan runs on low speed.
  • Swing Function (WAVEFLO® oscillation): (Remote control only) Activates louvers to oscillate for wider air distribution.
  • Compressor Indicator: An icon on the control panel indicates when the compressor is running.
  • LCDI Power Cord: Features TEST and RESET buttons to ensure proper functioning of the leakage current detection and interruption mechanism. Users are advised not to use these buttons as ON/OFF switches.

Installation:

The unit requires proper installation of exhaust hoses and a window kit for air conditioning, heating, and dehumidifying modes.

  • Exhaust Hoses: Two exhaust hoses are supplied. Hose adapters and window kit adapters screw onto the ends of the hoses.
  • Window Kit: The kit includes sliding panels designed to fit most vertical and horizontal window openings or sliding doors up to 8 ft. long. It can be configured for dual hose (recommended for efficiency) or single hose (for quick spot cooling) operation.
  • Placement: Choose a suitable location near a grounded electrical outlet and a window or door. Keep exhaust hoses as short and straight as possible.

Maintenance Features

  • Filter Cleaning/Replacement: The air filter should be cleaned every two weeks or as needed. Remove the filter from the compartment, wash it with warm water and neutral detergent, rinse, and dry thoroughly out of sunlight. Replace torn or unusable filters.
  • Unit Housing Cleaning: Keep the unit away from direct sunlight to prevent color fading. Clean the surface with a damp cloth and dry with a soft towel.
  • Emergency Condensate Holding Tank: The unit has an internal condensate tank that holds approximately 1.5 liters of water. When full, the unit automatically shuts off, and an indicator appears on the display. To drain, unscrew the screw plug at the bottom back of the unit and allow water to drain into a pan.
  • Storing the Unit: Before storing for an extended period or transporting, empty any excess water from the drain plug, unplug the unit, and store it in a cool, dry place.

Safety Precautions:

  • Always place the unit on a level surface.
  • Maintain at least 10 inches (25 cm) clearance around the unit.
  • Do not block air inlet or outlet grilles.
  • Connect to a correctly grounded power supply.
  • Do not use adapter plugs or extension cords.
  • Do not use near baths, showers, or swimming pools.
  • Do not insert objects into the air outlet.
  • Keep children away from the unit.
  • Inspect the power cord for damage before use; replace if damaged by a qualified technician.
  • Unplug the unit before cleaning.
  • Remove the venting kit from the window when the unit is not in use.

Soleus Air R-410A Specifications

General IconGeneral
BrandSoleus Air
ModelR-410A
CategoryPortable air conditioner
LanguageEnglish

Related product manuals