Sound Data Model 6 Model 3
Capacity Setting dBA dBA
Low 22.2 22.4
High 33.9 33.2
Boost 49.6 49.3
Note: All sound test were performed in an anechoic environment at 0.25m from the
Solo in question.
Significant improvement can be expected in a normal residential or commercial
environment with absorbent materials and surfaces
Sound and Application Data
As manufactured, Solo 6 is set such that the various capacities are as follows:
Airflow m3/hr Velocity Capacity @85C Capacity @65C Capacity@45C
Low 100 0.45m/sec 2.4kW 1.6kW 0.9kW
High 155 0.68m/sec 3.4kW 2.5kW 1.4kW
Boost 200 0.81m/sec 4.2kW 3.0kW 1.7kW
Based on entering air temperature 17C
As manufactured, Solo 3 is set such that the various capacities are as follows:
Airflow m3/hr Velocity Capacity @85C Capacity @65C Capacity@45C
Low 50 0.40m/sec 1.13kW 0.87kW 0.40kW
High 62 0.53m/sec 1.35kW 1.10kW 0.60kW
Boost 82 0.70m/sec 1.90kW 1.36kW 0.77kW
Based on entering air temperature 17C
All data applies only to Solo Discreet Range
Technical Manual