Permissibleratedcross-sectionforconnectingcables
at terminals 1 to 12: 1.5 mm² – 4.0 mm²
atterminals13to36:0.2mm²–1.5mm²
123 4 567 89 10 11 12
2
N
~ 230 V
~ 230 V
M
1
PE
PE
L1
N
1. Mains connection 230 V AC ± 10%
2. Motor connection (max. motor output 1000 W)
26 28 30 32 34 36
25 27 29 31 33 35
14 16 18 20 22 24
13 15 17 19 21 23
3. Install jumper (included in scope of delivery) if the following elements are not
connected:
Photocell:betweenterminals29and31
Anti-dropdevice:betweenterminals20and22
EmergencySTOPswitch:betweenterminals22and24
3-waybutton:betweenterminals17and19(Stopbutton)