7. Functions
7.1 Operator response when using a pre-end position switch
Seechapter6.4Connectingthepre-endpositionswitchonpage28.
7.2 Setting the early warning time (red potentiometer)
START
RADIO
ON
ON
OFF
OFF
board
MAX
ON
OFF
MAX
If required, you can set the early warning time using potentiometer 1. While the early
warningtimeisrunning,theinternallightingandtheexternalwarninglightash.
When set all the way to the left stop, this function is deactivated.
Inas-deliveredcondition,inthedoor"OPEN"position,theearlywarningtimeis
deactivated. You can change this reaction with a TorMinal (parameter: 19). When automatic
closing is activated, for safety reasons, there is a minimum early warning time of 3 seconds
before the door moves to "CLOSE." The maximum early warning time (turn potentiometer 1
clockwise) is approx. 30 seconds.