7. Functions
7.1 Operator response when using a pre-end position switch
Seechapter6.4Connectingthepre-endpositionswitchonpage28.
7.2 Setting the early warning time (red potentiometer)
START
RADIO
ON
ON
OFF
OFF
y
board
MAX
ON
OFF
MAX
If required, you can set the early warning time using potentiometer 1. While the early
warningtimeisrunning,theinternallightingandtheexternalwarninglightash.
When set all the way to the left stop, this function is deactivated.
Inas-deliveredcondition,inthedoor"OPEN"position,theearlywarningtimeis
deactivated. You can change this reaction with a TorMinal (parameter: 19). When automatic
closing is activated, for safety reasons, there is a minimum early warning time of 3 seconds
before the door moves to "CLOSE." The maximum early warning time (turn potentiometer 1
clockwise) is approx. 30 seconds.