62
Photocellwith
normally closed
contact
Receiver 24VDC,max.80mA*)
25
COM
29*)
NC
31*)
GND
33
Transmitter 24VDC,max.80mA*)
27
GND
35
Two-wire
photocell
Any polarity
29**)
31**)
*) Max.powerconsumptionappliesforthecontrolunitoverall:
at12V:60mA,at24V:80mA
**) ENISO13849-1:2008Cat.2,PLd
Maximum cable length for accessories on terminal strip 3: 30 m