7
These brief instructions are not a substitute
for the detailed Installation and Operating
Manual (overall manual).
They should be used as a guideline for
quick commissioning.
All safety instructions in the overall manual
must be followed!
All valid regulations and standards
for installation and operation must be
complied with without fail.
1. Motor connection
123 4 567 89 10 11 12
2
N
~ 230 V
~ 230 V
M
1
PE
PE
L1
N
TAUS
SAFETY
RADIO
16
12345678
DIP
ON
12345678
DIP
ON
Activate dead man mode; to do this,
setDIPswitch8tothe"OFF"position.
Activate the respective direction of movement
with the buttons in the housing cover. If the
door moves in the wrong direction:
-Disconnectthecontrolunitfromthemains.
-Switchthelinesatterminals6and7.
If necessary, correct the end position setting
in accordance with the installation instructions
from the motor manufacturer.
For more information, see overall manual,
chapter:
3.2 "Connecting the control unit"
4.2 "Checking the running direction of
the motor"
2. Checking the wiring of any unused
inputs
26 28 30 32 34 36
25 27 29 31 33 35
14 16 18 20 22 24
13 15 17 19 21 23
The following terminal pairs must be
connected to each other with wire jumpers or
corresponding normally closed (NC) contacts:
Terminal29and31->Photocell
Terminal20and22->Anti-dropdevice
Terminal22and24->EmergencySTOP
switch
Terminal17and19->3-waybutton,Stop
3. Connection of electrical safety contact strip.
(Version8.2kΩ)
213
4
7
8
12 13
10
6
123 4 567 89 10 11 12
NN
PE
N
~ 230 V
~ 230 V
M
PE
L1
14 16 18 20 22 24
13 15 17 19 21 23
STOP
5
26 28 30 32 34 36
25 27 29 31 33 35
24 V
24 V
GND
29 31
GND
12 V
12 V
GND
N
PE
32 34
8k2
3.1. No settings need to be made on the
control unit. The control unit tests and
recognises which variant is connected during
eachself-test(whenthemainsvoltageis
switched on or an end position has been
reached).
Brief instructions
(only use in combination with the original Installation and Operating Manual)