EasyManua.ls Logo

SOMNOmedics SOMNOtouch NIBP - User Manual

Default Icon
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SOMNOmedics GmbH Am Sonnenstuhl 63 D-97236 Randersacker
Phone: (+49) 931 / 35 90 94-0 Fax: (+49) 931 / 35 90 94-49
E-Mail: info@somnomedics.de Internet: www.somnomedics.eu
SOMNOtouchNIBP
I
NSTRUCTION MANUAL

Table of Contents

Questions and Answers

Summary

Introduction

Intended Use

Describes the intended use of the SOMNOtouch™ NIBP for recording physiological signals and diagnosing cardiovascular disorders.

About this instruction manual

Explains the importance of reading the manual, especially sections with warning icons indicating potential dangers.

Explanation of Symbols used in this Manual

Details the meaning of symbols used in the manual, including hints, tips, and warnings for patient safety.

Patients

Specifies the age range and patient exclusions for using the SOMNOtouch NIBP and its components.

About the SOMNOtouch NIBP

Model and Device Number

Provides guidance on checking the model and device number upon unpacking and comparing it with the delivery note.

Elements of keyboard

Describes the function and status indicators of the device's buttons and LEDs.

Configuration

Lists the components included in the SOMNOtouch™ NIBP package and the available channels for recording.

Blood pressure determination using the SOMNOtouch NIBP

Explains the principle of blood pressure determination using Pulse Transit Time (PTT) and necessary analysis parameters.

Safety instructions

Installing the DOMINO light Software

Updating the Software

Details the process of updating the software version and choosing installation types.

Manual Docking Station Driver Installation

Windows 7

Provides step-by-step instructions for installing the docking station driver on Windows 7.

Windows 10

Provides step-by-step instructions for installing the docking station driver on Windows 10.

Operating Instructions

Initialising the SOMNOtouch NIBP

Explains the process of initializing the device, including PC and direct display initialization.

Starting the SOMNOtouch NIBP at the display

Details how to start a measurement directly on the device display, including sensor application.

Application of the sensors

Provides instructions on how to correctly apply the device wristband, ECG electrodes, and SpO2 sensor.

Initial Blood Pressure Calibration

Describes the mandatory step of performing a manual blood pressure measurement for calibration.

Display during the measurement

Explains the information displayed on the screen during recording and how to access settings.

Settings

Details how to adjust device settings such as Bluetooth, Sound, Display, and Language.

Data Transfer from SOMNOtouchTM to PC

Explains the procedure for transferring recorded data from the device to a computer.

Firmware Update

Describes the process and requirements for updating the device firmware.

Open a Recorded Measurement

Guides users on how to open and manage recorded measurements within the DOMINO light software.

Analysis

Covers various analysis functions like blood pressure calibration, defining measurement periods, and using plots.

Open the Report

Explains how to select and generate reports using different templates.

DOMINO light Software

System Requirements

Lists the minimum and recommended system requirements for running the DOMINO light software.

DOMINO light Panel

Describes the icons and functions available on the DOMINO light software panel.

Global Preferences

Explains how to configure global settings, including folder management and registration.

Menu - Channels

Details how to configure channel display settings like color, scaling, and order.

Menu - Analysis

Covers the configuration of built-in analysis algorithms and display settings.

Menu - Analysis Channels

Explains how to format the analysis window presentation and adjust channel settings.

Menu - Filter

Details how to apply filters (Highpass, Lowpass, Notch) to specific signals.

Menu - Keys

Describes how to set keyboard keys for manual editing of events and markers.

Menu - Markers

Explains how to add, rename, and delete markers to indicate events within a measurement.

Menu - Area Definition

Details how to define custom areas for analysis and how detected events are itemized in reports.

Menu - User Data

Covers the entry of user information and logo customization for report headings.

Menu - Report

Explains how to configure report templates, set contents, format, and order of report items.

Analysis

Details how to set analysis and channel parameters directly or via Global Preferences.

Functions of the Pop-up Window

Describes functions accessible via pop-up windows in the Analysis and Raw Data views.

Layouts for Data Display in Analysis Mode

Explains the different display layouts selectable for efficient data processing.

Inserting Markers

Provides instructions on how to place markers in the Raw Data window at specific positions.

Deleting, Editing, Adding Markers

Explains how to manage markers, including adding, editing, deleting, and hiding them.

Creating and Editing Samples

Details how to select and save interesting events as samples for reports.

The Event List

Describes how to open and view the event list for analysis.

Edit Modes

Introduces the four techniques for manually editing events in the Raw Data: Edit, Quick Edit, Select Edit, and Repeat Modes.

Reports

Explains the two methods for generating reports using the DOMINO light software.

Form Letters

Describes the facility to generate form letters for sending diagnostic information.

Creating a Form letter

Provides a step-by-step guide on creating new form letters and selecting fields.

Data Exchange

Details options for exporting data in various formats and exchanging data between labs.

Data Export as Picture, in RIFF or ASCII Format

Explains how to export analysis and raw data as pictures or data files.

EDF+ Export

Describes the EDF+ export feature for data exchange between different sleep labs and devices.

Export to external ECG analysis program

Explains how to export ECG data in .scp file format for external analysis programs.

Archiving

Recommends archiving analyzed recordings regularly and deleting them from the hard drive.

Archiving data

Provides instructions on how to archive data by burning it onto CDs or DVDs.

Archiving database

Explains the recommended weekly archiving procedure for the patient database.

Patient Database (Option)

Describes the patient database features, including information, search, and trends.

Registration

Explains the requirement for a registration code to use the patient database.

Search Function

Details how to search for patients and recordings using various criteria.

Menu - History

Covers editing patient data, adding information, and creating PDF documents from historical records.

Menu - Recording

Explains how to display sleep profiles, analyzed results, and open reports from the recording menu.

Menu - Summary Picture

Describes the menu that displays summary graphics from the patient's analysis curves.

Flowchart of the menu navigation

Troubleshooting

Maintenance of the SOMNOtouch

Maintenance rate

Specifies the recommended maintenance schedule for the device, including inspection and calibration.

Cleaning and disinfection

Provides instructions for cleaning and disinfecting the device and its accessories.

Use and Maintenance of the Rechargeable Battery

Explains the features of the rechargeable battery and proper charging procedures.

Service

Technical specification

Lists the technical specifications of the SOMNOtouch™ device, including channels, processing, and dimensions.

Lifetime

States the expected lifetime of the SOMNOtouch™ device.

Storage

Provides guidelines for storing the device and sensors when not in use.

Transport

Specifies the requirements for safely transporting the device.

Operating and Storage;Transport conditions

Outlines the recommended environmental conditions for operating, storing, and transporting the device.

Malfunctions

Guides users on how to handle and report device malfunctions.

Warranty

Details the conditions and period covered by the SOMNOmedics warranty.

Disposal of Parts and;or the SOMNOtouchTM device

Provides information on the proper disposal of device parts and the unit according to regulations.

Advice on the electromagnetic compatibility

States that information on electromagnetic compatibility is available upon request.

Accessories and Spare Parts

Lists available accessories and spare parts for the SOMNOtouch™ device.

Contact

Provides contact information for customer service, support, and technical assistance.

Notes

An empty section for user notes.

SOMNOmedics SOMNOtouch NIBP Specifications

General IconGeneral
BrandSOMNOmedics
ModelSOMNOtouch NIBP
CategoryBlood Pressure Monitor
LanguageEnglish