EasyManua.ls Logo

SonicWALL TZ300 - Page 9

SonicWALL TZ300
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Selecttheradiobut tonfortheWirelessGuide
wizard.
ClickNextandfollow thepromptsintheWireless
Guidewizard.Formoreinformationandcomplete
procedures,refertothelatestSonicOS
AdministrationGuide.
Forinternational(nonUSAorJapan)TZWireless
appliances,youareaskedtoselectacountrycode
when
usingtheWirelessGuideorwhenyouinitiallynavigateto
theWireless>Settingspage.Besuretoselectthecountry
codeforthecountryinwhichtheappliance willbe
deployed,evenifyouarenotcurrentlyinthatcountry.
IMPORTANT:IfyouselectthecountrycodeforCanada,it
cannotbechangedexceptbycontactingSonicWall
Support.
6 Registerproduct
Pointyourbrowsertotheappliance LANIPaddr ess
(default
https://192.168.168.168)andlogin
usingtheadministratorcredentials.
ClickRegisterontheSystem>Statuspageunderthe
SecurityServicessection.
LoginusingyourMySonicWallaccountnameand
password.IfyoudonothaveaMySonicWallaccount,
TIP:RegisteringtheappliancefromSonicOSrequiresthat
DNSServersettingsareconfiguredontheWAN(X1)
interface.
clicktheCr eateMySonicWallaccountlinktocreate
anaccount.
MySonicWalldirectlyobtainsthenecessary
informationfromtheTZappliance.Whenfinished,
youwillsee amessagethatregistrationhasbeen
completed.ClickContinue.
NOTE:Yourappliance mustberegisteredtodownload
thelatestfirmware.
7 Get thelatestfirmware
InaWebbrow ser,navigateto
http://ww w.mysonicwall.com
ClickDownloadsandselectTZ300orTZ300W
FirmwarefromtheSoftwareTypedropdownmenu.
Clickthelinkforthefirmwareyouwantandsavethe
filetoalocationonyourcomputer.
OntheTZappliance,navigatetotheSystem
>
Settingspage.ClicktheUploadNewFirmware
button.
ClicktheBrowsebuttontoselectthefirmwareyou
justdownloaded.
ClickUploadandwaitfortheuploadtocomplete.
IntheFirmwareManagementTable,clicktheBoot
iconforyournewfirmware.
8 MountingtheTZappliance
Foroptionalwallmounting ,youneed:
Screwdriver
Drill withappropriatesizebit
Formountingondrywall:
Two#6panheadscrews,1inchlong(7mm
diameterhead,25mmlong)
Twowallanchors
Formountingonsolidwoodormetal:
Two#6panheadwoodormachinescrews,1
inch
long(7mmdiameterhead,25mmlong)
Tomounttheapplianceonthewall:
1Drilltwoholes4.5inches(11.5cm)apartinthewall
where youwanttomounttheappliance.
2Ifusingwallanchors,insertawallanchorintoeach
hole.
3Insertascrewintoeachwallanchor(int oeachhole
if
notusingwallanchors),leaving3/16inches(0.45cm) of
thescrewsexposed(includingscrewhead).
4 Positiontheappliancemountingslotsoverthescrews
andpressinanddownuntiltheapplianceissecurely
mounted.
WARNING:Donotmounttheapplianceontheceiling,it
isnotdesignedforsecureceilingmounting.
9 Safetyandregulatoryinformation
Installingtheappliance
Installinalocationawayfromdirectsunlightandsourcesofhea t.Amaximumambient
temperatureof104ºF(40ºC)isrecommended.
Routecablesawayfrompowerlines,fluorescentlightingfixtures,andsourcesofnoisesuch
asradios,transmitters,andbroadbandamplifiers.
Theincludedpowercord(s)areapprovedforuseonly
inspecificcountriesorregions.Before
usingapowercord,verifythatitisratedandapprovedforuseinyourlocation.
Ensurethatnowaterorexcessivemoistur ecanentertheunit.
Allowunrestrictedairflowaroundtheunitandthroughtheventsonthesideoftheunit.A
minimum
of1inch(25.44mm)clearanceisrecommended.
Considerationmustbegiventotheconnectionoftheequipmenttothesupplycircuit.
Appropriateconsiderationofequipmentnameplateratingsmustbeusedwhenaddressing
thisconcern.Donotoverloadthecircuit.
Thisequipmentisnotintendedforuseatworkplaceswithvisualdisplay
units,inaccordance
with§2oftheGermanordinanceforworkplaceswithvisualdisplayunits.Toavoid
incommodingreflectionsatvisualdisplayworkplacesthisdevicemustnotbeplacedinthe
directfieldofview.
Lithiumbatterywarning
TheLithiumBatteryusedintheSonicWall securityappliancemaynotbereplacedbythe
user.ReturntheSonicWallsecurityappliancetoaSonicWallauthorizedser vicecenterfor
replacementwiththesameorequivalenttyperecommendedbythemanufacturer.If,for
anyreason,thebatteryorSonicWallsecurityappliancemustbedisposedof,dosofollowing
thebatterymanufacturer'sinstructions.
Cableconnections
AllEthernetandRS232(Console)cablesaredesignedforintrabuildingconnectiontoother
equipment.Donotconnecttheseportsdirectlytocommunicationwiringorotherwiring
thatexitsthebuildingwheretheSonicWallapplianceislocated.
Powersupplyinformation
IfthepowersupplyismissingfromyourSonicWallproductpackage,pleasecontact
SonicWallTechnicalSupportathttps://support.sonicwall.com/contactsupportfora
replacement.ThisproductshouldonlybeusedwithaULlistedpowersupplymarked“I.T.E.
LPSwithanoutputrated12VDC,minimum2.0A,Tma:minimum40degreeC.
WARNING:Foryoursafety,followallinstructionslisted
inthissection.
EUandEFTA
ThisdeviceisapprovedforuseinEUmemberstatesandEFTAcountriesasshownonthe
appliancelabel.
Declarationofconformity
A“DeclarationofConformityinaccordancewiththedirectivesandstandardshasbeen
madeandisonfileatSonicWallInt ernationalLimited,CityGatePark,Mahon,Cork,Ireland.
CEdeclara tionscanbefoundonlineathttps://support.sonicwall.com.
台灣 RoHS
限用物質含有情況標示資訊請參考下列網址 :https://support.sonicwall.com.
操作說明 :
VerwarnungWeiterehinweisezur
montage
hlenSierdieMontageeinenOrt,derkeinemdirektenSonnenlichtausgesetztistund
sichnichtinderhevonWärmequellenbefindet.DieUmgebungstemperaturdarfnicht
mehrals40°Cbetragen.
hrenSiedieKabelnichtentlangvonStromleitungen,LeuchtstoffröhrenundStörquellen
wieFunksendernoderBreitbandverstärk ern.
DasimLieferumfa ngenthaltenebzw.die
imLief erumfangenthaltenenNetzkabelsindnur
TZ300W(RM:APL280B5)RFTransmitterBandsandPower
FrequencyBand MaximumRadioFrequencyPowerTransmitted
MHz dBmEIRP
2412‐2472 19.06
5180‐5240 22.19
5260‐5320 22.07
5500‐5700 26.29
NOTE:Additionalregulatorynotificationsandinf ormationforthisproductcanbefound
onlineathttps://support.sonicwall.com.
輸入產品型號並搜尋
選擇 TechnicalDocumentation
選擇 SafetyandRegulatoryReferenceGuide
Downloadthisdocument 下載此文件
rdieVerwendunginbestimmtenndernundRegionenzugelassen.ÜberprüfenSiebitte
vorderVerwendungeinsNetzkabels,obesrdieVerwendunginIhremLandoderIhrer
RegionzugelassenistunddengefordertenNormenentspricht.
StellenSiesicher,dassdasGerät
vorWasserundhoherLuftfeuchtigkeitgeschütztist.
StellenSiesicher,dassdieLuftumdasGerätherumzirkulierenkannunddieLüftungsschlitze
anderSeitedesGehäusesfreisind.HieristeinBelüftungsabstandvonmindestens26mm
einzuhalten.
PrüfenSiedenAnschlussdesGerä tsandieStromversorgung,damitderÜberstromschutz
sowie
dieelektrischeLeitungnichtvoneinereventuellenÜberlastungderStromversorgung
beeinflusstwerden.PrüfenSiedabeisorgfältigdieAngabenaufdemAufkleberdesGeräts.
ÜberlastenSienichtdenStromkreis.
DiesesGerätistnichtzurVerwendunganArbeitsplätzenmitvisuellenAnzeigegeräten
gemäß§2derdeutsche nVerordnungfürArbeitsptzemitvisuellenAnzeigegeräten
vorgesehen.
UmstörendeReflexionenamBildshirmarbeitsplatzzuvermeiden,darfdiese s
ProduktnichtimunmittelbarenGesichtsfeldplatziertverden.
Verwarnunghinweiszurlithiumbatterie
DieinderInternetSecurityAppliancevonSonicWallverwendeteLithiumbatteriedarfnicht
vomBenutzerausgetauscht werden.ZumAustauschenderBatteriemussdieSonicWallin
einvonSonicWallautorisiertesServiceCentergebrachtwerden.DortwirddieBatterie
durchdenselbenoderentsprechenden,vomHerstellerempfohlenenBatterietypersetzt.
BeachtenSiebeieinerEn tsorgungderBatterieoderderSonicWallInternetSecurity
AppliancediediesbeglichenAnweisungendesHers tellers.
Verwarnungkabelverbindungen
AlleEthernet‐undRS232CKabeleignensichrdieVerbindungvonGerätenin
Innenräumen.SchließenSieandieAnschlüssederSonicWallkeineKabelan,dieausdem
Gebäudeherausgeführtwerden,indemsichdasGerätbefindet.
Informationenzurstromversorgung
WenndieStromversorgungvonderSonicWallProduktpaketfehlt,wendenSonicWallden
TechnischenSupportunterhttps://support.sonicwall.com/contactsupport.
DiesesProduktsolltenurmiteinemrdenEuropäischenMarktgenehmigtenNetzteilmit
demLogo"I.T.E.LPS"undeinerAusgangsleistungvon12VDC,mind.2.0 A,Tma:mind.40
GradC,betriebenwerden.

Related product manuals