Bind Temperature Control Device
There is a built-in temperature sensor in the NSPanel to monitor the room temperature and you
can maintain the room temperature by controlling the cooler/heater, which is connected with
smart switches or smart plus and these devices are required to pair with eWeLink App.
Access the NSPanel interface in the App and tap “Thermostat” to select the devices in the Action
device list. All the listed devices are supported to bind with the Thermostat (including two
NSPanel channels). You can only select one device or one channel of the multi-channel device
to execute and then choose heater or cooler as the Device type.
Active the Thermostat after selecting the Action device and Device type, then you can see there
are two modes to control the temperature which are Manual mode and Auto mode.
Manual mode:
Allow you to adjust the temperature manually whenever you want and then the Thermostat will
execute to maintain the manual setting temperature.
Auto mode:
Allow you to set 6 target temperature at most by tapping “Add” to set the temperature respectively.
Once set, all setting will execute automatically at certain time duration and cannot be controlled
manually unless switched to the Manual mode. The binding devices will turn off when they are
out of schedule.
Actual room temperature will be ±1℃. For example, the setting temperature is 26℃ but the
actual temperature range is between 25℃ and 27℃.