18
CFD-G505
digital
voltmeter
100 k
Ω
TP (VT)
i
jack (J391)
set
32
Ω
level meter
(range: 0.5–5 V ac
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
TP (FM IN)
FM RF signal
generator
0.01
µ
F
set
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
TUNER SECTION 0 dB = 1 µV
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: AM
• Connecting Level Meter (FM, AM)
• Connecting Digital Voltmeter (FM, AM)
•Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 530 kHz 1,710 kHz
Reading on Digital voltmeter 1.0 ± 0.05 V 5.3 ± 0.7 V
Adjustment Part L4 <confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 CT3
620 kHz 1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 87.5 MHz 108 MHz
Reading on Digital voltmeter 1.3 ± 0.3 V 3.0 ± 0.2 V
Adjustment Part <confirmation> L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 CT1
87.5 MHz 108 MHz
Adjustment Location: See page 19.
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM