EasyManua.ls Logo

Sony Magnescale MD20A - User Manual

Sony Magnescale MD20A
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
取扱説明書/ Instruction Manual
第2版(改訂1)/ 2nd Edition (Revised 1)
デテクタ/ Detector
MD20A
/
お買い上げいただき、ありがとうございます。
ご使用の前に、この取扱説明書を必ずお読みください。
ご使用に際しては、この取扱説明書どおりお使いください。
お読みになった後は、後日お役に立つこともございますので、必ず保管してください。
Read all the instructions in the manual carefully before use and strictly follow them.
Keep the manual for future references.
Question and Answer IconNeed help?

Do you have a question about the Sony Magnescale MD20A and is the answer not in the manual?

Summary

1. NOTES TO USERS

1-1. General Precautions

General safety and usage advice for proper operation.

2. INTRODUCTION

3. FEATURES

4. SPECIFICATIONS

Power Requirements

Details on the power supply needed for the detector.

Power Consumption

Information on the maximum power the detector consumes.

Operating Temperature Range

Specifies the acceptable operating temperature range.

Storage Temperature Range

Specifies the acceptable storage temperature range.

Outside Dimensions

Physical dimensions of the detector unit.

Mass

The weight of the detector unit.

Accessories

List of included accessories with the detector.

5. OPERATION

5-1. Names of Parts

Identification of the detector's main parts and controls.

5-2. Resolution Setting

Procedure for setting the detector's resolution using a rotary switch.

5-3. Output Pulse Width Setting

Procedure for setting the output pulse width using a rotary switch.

5-4. Direction Switching

Changing the pulse output correlation with scale travel direction.

5-5. Using the Reference Point

Instructions for using the high-precision reference point signal.

5-6. The Reference Point when Using a FANUC NC Machine

Specific guidance for using the reference point with FANUC NC systems.

5-7. Power Supply Connections

Instructions for connecting the power supply to the detector unit.

5-8. Alarm Signal

Explanation of alarm signal triggers and system behavior.

5-9. Detector Mounting

Procedure for mounting the detector unit and linking multiple units.

6. ADJUSTMENT

6-1. Scale Signal Adjustment

Procedure to adjust scale signal for stable operation by minimizing ripple.

6-2. Reference Point Adjustment

Procedure for adjusting the reference point gate position.

Instructions for connecting the detector to a Sony NC

Specific instructions for integrating the detector with Sony NC systems.

7. INPUT;OUTPUT CABLE CONNECTOR SPECIFICATIONS

7-1. Head Cable Connector

Specifications and pinout for the head cable connector.

7-2. Reference Point Connector

Specifications and pinout for the reference point connector.

7-3. Output Connector

Specifications and pinout for the output connector.

Output Specifications

8. OUTSIDE DIMENSIONS

Sony Magnescale MD20A Specifications

General IconGeneral
BrandSony
ModelMagnescale MD20A
CategorySecurity Sensors
LanguageEnglish

Related product manuals