Procedure:
1.
Keep the set horizontal.
(
If
the set is not horizontal, this adjustment cannot be )
performed due to the gravity against the 2-axis device.
2.
Insert disc (YEDS-18) and press [> PLA Y button.
3.
Connect oscilloscope to
TP
(FEO) and
TP
(VC)
on
BD
board.
4.
Adjustment RV101
on
BD
board so
that
the
waveform
is as shown in the figure below. (focus gain adjustment)
VOLT/DIV:
lOOmV
TIME/DIV:
2mS
Incorrent Examples
(DC
level changes more than on adjust-
ed waveform)
low focus gain
high focus gain
VOLT/DIV:
lOOmV
TIME/DIV:
2mS
VOLT/DIV:
lOOmV
TIME/DIV:
2mS
5.
Connect oscilloscope to
TP
(TEO) and
TP
(VC)
on
BD
board.
6.
Adjusted MV102
on
BD
board so
that
the
waveform
is
as
shown
the
figure below. (tracking gain adjustment)
VOLT/DIV:
lV
TIME/DIV:
2mS
Incorrect Examples (fundamentia wave appears)
low
tracking
gain
VOLT/ DIV : 1 V
TIME/DIV:
2mS
-ov
-5-
high tracking gain
(
high fandamential wave)
than for low gain
Adjustrnent Locations :
(8D
board]
- conductor side -
(Main board]
- component side -
- conductor side -
b TP
(ADJ)
CDP-HSOO
VOLT/DIV:
lV
TIME/DIV:
2mS
-ov
IC301
0D
(PCK)