Record
Bias
Adjustment
Setting
:
REC
LEVEL
control:
standard
record
(See
page
4.)
Procedure
:
1,
Mode:
record
AF
OSC
blank
tape
10k
Q
CS-17
S}
25mV
(—380dBs)
1)
316Hz
2)
10KHz
2.
Mode:
playback
recorded
LINE
OUT
Confirm
that
the
10kHz
playback
output
is
00.5dB
ralative
to
the
315Hz
output,
If
necessary,
adjust
RV42
(L-CH),
RV62
(R-CH)
and
repeat
the
steps
given
above.
Adjustment
Location
:
HX
PRO
board
Recording
bias
adjustmnet
7
eaaeenenimmeamamenm
RV42 RV62
(L-CH)
(R-CH)
ina
em
Recording
(ec
see
RV101
adjustment
(L-CH)
Record
Level
Adjustment
Setting
:
REC
LEVEL
control:
standard
record
(See
page
4.)
Procedure
:
1,
Mode:
record
Oe
blank
tape
ORS
CS-17
attenuator
“al.
315Hz,
0,044V
(—25dBs)
2.
Mode:
playback
recorded
portion
{
oes
3,
Play
back
the
signal
recorded
in
step
1.
Confirm
that
the
signal
level
is
within
the
specification
below.
If
necessary,
adjust
RV101
(L-CH),
RV201
(R-CH)
and
repeat
the
step
1-3,
Specification
:
LINE
OUT
level:
—25dB+0.5dBs
(0,041~0.046V)
Adjustment
Location
:
MAIN
board