391
Setting Flip-Flop Mode
You can enable/disable flip-flop mode. When disabled,
bus fixed mode is selected.
1
Open the Home > Setup > Switcher > Custom >
Transition menu (19103.41).
2
Select the target switcher bank to set.
3
Enable/disable using the [Bus Toggle] switch.
On: Flip-f
lop mode
Off: Bus fi
xed mode
Setting the Preset Color Mix Mode
1
Open the Home > Setup > Switcher > Custom >
Preset Color Mix menu (19103.42).
2
Select the target switcher bank to set.
3
Press the [Stroke Mode] button and select a stroke
mode from the pull-down list.
Normal: Normal
mode
Execute a preset color mix with two transition
operat
ions.
Single: Single mode
Execute a preset color mix with one transition
operat
ion.
In bus fixed mode, single mo
de (fixed) is selected.
4
Press the [Edit] button for [Non Drop Key].
The [Set Non Drop Key] window appears.
5
Place a check mark in the keys to keep their insertion
status.
You can select multiple keys.
6
Press [OK].
7
Enable/disable one-time mode using the [One Time
Enable] switch.
On: Re
turn to previous transition type after a
transition ends.
Off: Mai
ntain a preset color mix after a transition
ends.
Enabling/Disabling Split Faders
You can enable/disable split faders on the simple-type
transition control block.
When a switcher bank is set to flip-flop mode, split faders
are di
sabled.
1
Open the Home > Setup > Switcher > Custom >
Transition menu (19103.41).
2
Select the target switcher bank to set.
3
Enable/disable using the [Split Fader] switch.
On: Enable
split faders.
Off: Disable
split faders.
Enabling/Disabling Fade-To-Black
You can enable/disable fade-to-black for each program
output (PGM1 to PGM4).
1
Open the Home > Setup > Switcher > Custom >
Transition menu (19103.41).
2
In the [FTB] group, select the program outputs
(PGM1 to PGM4) to enable.
When the switcher ba
nk operation mode is standard
mode, the [PGM2] to [PGM4] buttons cannot be
selected.
Setting the DME Wipe Edge
Softness Function
You can display the input image so that it fills the frame
when executing a DME wipe by disabling the edge
softness function.
Disabling will disable the edge softness function in any of
the following
cases.
When [Crop] is disabled in the [Crop Mode] group in
t
he Bus/Transition > DME Wipe > Modify menu of a
switcher bank
When [Crop] is enabled in the [Crop Mode] group in
t
he Bus/Transition > DME Wipe > Modify menu of a
switcher bank and the [Top] and [Right] parameters are
set to “100.00” and the [Left] and [Bottom] parameters
are set to “–100.00”
When the DME wipe direction is reverse and before
e
xecution of a transition