DIGORA
®
Optime DXR-50 001
Digital intraoral imaging plate system
Users Manual
Document no. 204253 rev. 6 (2012-05)
ENGLISH
DIGORA
®
Optime DXR-50 001
Digital intraoral imaging plate system
Users Manual
Document no. 204253 rev. 6 (2012-05)
ENGLISH
Reviewed: Taskinen Jari Pekka 29.05.12 11:37:01
Approved: Äärynen Teemu 29.05.12 14:52:44
See the PaloDEx Group Oy PDM system to determine the status of this document. Printed out: 28.08.12 13:43:18 D504182
Approved

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Soredex DIGORA Optime DXR-50 001 and is the answer not in the manual?

Summary

The DIGORA Optime

1.1 Introduction

Overview of the DIGORA Optime digital imaging plate unit and system components.

1.2 System Installation

Instructions for setting up the DIGORA Optime imaging plate system.

Intraoral imaging plate unit

2.1 Main Parts and Controls

Identification and description of the main components and controls of the imaging plate unit.

2.2 Accessories

Details on available accessories for the DIGORA Optime system, including imaging plates and covers.

2.3 Display Symbols and What They Mean

Explanation of symbols and animations displayed on the unit for status indication and operation.

Using the system

3.1 General

General guidelines for using the DIGORA Optime system, including accessory recommendations.

3.2 Preparing the System

Steps to prepare the system for operation, including PC and software setup.

3.3 Preparing an IP for Exposure

Procedure for preparing an imaging plate (IP) with a protective cover for X-ray exposure.

3.4 Imaging Plate Holders

Recommendations for using imaging plate holders to improve image quality and positioning.

3.5 Taking an Exposure

Instructions on how to perform an X-ray exposure using the imaging plate system.

3.6 Reading an Imaging Plate

Procedure for reading an exposed imaging plate (IP) with the DIGORA Optime unit.

3.7 Removing IPs from the Plate Collector

Guidance on safely removing imaging plates from the unit's plate collector.

3.8 Standby Mode

Description of the unit's standby mode and how it exits this state.

3.9 Retrieve Last Image

Steps to retrieve the last scanned image if it was not transferred to the PC.

3.10 Shutting Down the Unit

Procedure for correctly powering down the DIGORA Optime unit.

3.11 IP Erasing Mode (Initial Erasing of the IPs)

How to perform an initial erase procedure on imaging plates before first use.

3.12 Taking an Occlusal Projection Image

Specific instructions for capturing occlusal projection images using the Comfort Occlusal 4C kit.

3.13 Errors and Warnings

Information on common errors, warnings, and troubleshooting steps for the unit.

Handling and care of imaging plates

4.1 General

General principles for handling imaging plates to ensure image quality and longevity.

4.2 Handling

Specific techniques and precautions for handling imaging plates to prevent damage and contamination.

4.3 Cleaning

Methods for cleaning imaging plates, including recommended solutions and what to avoid.

4.4 Storage

Guidelines for proper storage of imaging plates to maintain their condition and performance.

4.5 Replacement

Criteria for replacing imaging plates due to image quality issues or physical damage.

4.6 Disposal

Information on the proper disposal of imaging plates in accordance with regulations.

Unit care and maintenance

5.1 Cleaning the Unit

Instructions for cleaning the exterior and accessible parts of the imaging plate unit.

5.2 Disinfecting the Unit

Procedures for disinfecting the unit, including safety precautions and suitable solutions.

5.3 Maintenance

Information regarding the maintenance requirements for the imaging plate unit.

5.4 Repair

Guidelines for obtaining repair services for the unit, emphasizing authorized personnel.

5.5 Disposal

Procedures for disposing of the unit and its accessories according to environmental regulations.

Symbols That Appear On or In The Unit

Warnings and Precautions

Appendix A. Technical Specifications

A.1 Unit

Detailed technical specifications for the DIGORA Optime intraoral imaging plate unit.

A.2 Imaging Plates and Hygiene Bags

Specifications and details for imaging plates (IPs) and associated hygiene bags.

A.3 Main Dimensions

Physical dimensions of the DIGORA Optime unit.

Guidance and Manufacturers Declaration - Electromagnetic Emissions

Information on electromagnetic emissions and compliance for the DXR-50 unit.

Guidance and Manufacturers Declaration - Electromagnetic Immunity

Information on electromagnetic immunity and compliance for the DXR-50 unit.

Appendix B. Installation and Setup

B1 System Installation

Procedures for the initial installation of the DIGORA Optime system components.

B2 Connecting the Unit to a PC; LAN

Methods for connecting the imaging plate unit to a PC or local area network (LAN).

B3 Setup Options

Configuration settings for the scanner via the dental imaging software.

B4 Troubleshooting

Common problems and solutions for the DIGORA Optime system.

Soredex DIGORA Optime DXR-50 001 Specifications

General IconGeneral
BrandSoredex
ModelDIGORA Optime DXR-50 001
CategoryAll in One Printer
LanguageEnglish