EA-R03 Wireless Keypad Controller Kit
Operating Instructions
J-EA-R03-M_revC visit www.southco.com for latest version of this document Page 1 of 4
Package Contents
EA-R02-202 Receiver
EA-R03-103 Wireless Keypad Transmitter
Keypad Mounting Packet
Power/Auxiliary Connector Wire Harness
Lock/Unlock Relay Connector Wire Harness
User Instructions
EA-R03-103 Wireless Keypad Transmitter
1·2 3·4
5·6 7·8
9·0
1·2 3·4
5·6 7·8
9·0
EA-R02-202 Receiver
1. Antenna
2. Access Tab for Programming Switches
Features
Receiver supports up to four transmitters (one pre-programmed
wireless keypad transmitter included with kit)
Re-programmable user code (3 to 7 digits)
Selectable LOCK/UNLOCK pulse duration (250ms or 10sec)
Backlit keypad keys
Two user-configurable lock/unlock relay outputs
One 12V auxiliary relay output.
Specifications
Receiver Power: 12VDC (±10%)
Receiver Idle Current: 10mA (maximum), no attached devices
Receiver Operating Current: 100mA (maximum), no attached devices
Receiver Outputs: three Form C relays, rated 15A at 14VDC
Receiver Operating Temp: -20 to 80°C
Operating Range: up to 60 feet / 18 meters (open air)
Operating Frequency: 433.92MHz
Coding Type: Fixed Code (24-Bit)
Transmitter Power: Type CR2032 3VDC battery
Normal Use
The keypad transmitter can be used to lock and unlock the system.
Unlocking the System
Enter the user code (default 1234), then press the 1·2 button. The system
will unlock and the auxiliary output will pulse twice, as shown in the figure
below:
UNLOCK Sequence (pulse set for 250ms)
UNLOCK Sequence (pulse set for 10 seconds)
Locking the System
Enter the user code (default 1234), then press the 3·4 button. The system
will lock and the auxiliary output will pulse once, as shown in the figure
below:
LOCK Sequence (pulse set for 250ms)
LOCK Sequence (pulse set for 10 seconds)
Pulsing Auxiliary Output
Enter the user code (default 1234), then press the 5·6 button. The auxiliary
output will pulse five times, as shown in the following figure:
Question and Answer IconNeed help?

Do you have a question about the Southco EA-R03 and is the answer not in the manual?

Summary

Normal Use

Unlocking the System

Describes how to unlock the system using the keypad transmitter with the default user code.

Locking the System

Details the procedure for locking the system via the keypad transmitter and user code.

Pulsing Auxiliary Output

Explains how to activate the auxiliary output to pulse five times using the keypad.

Changing the User Code

Enrolling Transmitters and Setting Pulse Duration

Enrolling Transmitters

Instructions for enrolling up to four compatible transmitters with the receiver unit.

Setting LOCK;UNLOCK Pulse Duration

Procedure to set the LOCK/UNLOCK output pulse duration to 250ms or 10 seconds.

Resetting the User Code

Transmitter Battery Replacement

Receiver Unit Mounting and Wiring

Safety Precautions

Compliance Information

FCC Compliance Statement

Statement regarding compliance with FCC Rules, Part 15.

R&TTE Compliance Statement

Statement on compliance with EU Directive 1999/5/EC.

EU Countries Intended for Use

Details EU countries where the ETSI version is authorized for use.

Southco EA-R03 Specifications

General IconGeneral
Product CategoryElectronic Access Controller
FinishBlack
Voltage12-24 VDC
Communication ProtocolWiegand
Operating Temperature-20°C to +60°C (-4°F to +140°F)
Reader CompatibilityWiegand
Inputs2 Inputs (Request-to-Exit, Door Status)
Outputs2 relay outputs
Dimensions80mm