Do you have a question about the Spa Sciences ZIVA and is the answer not in the manual?
Charge fully for 12 hours before first use, even if indicator light changes, for up to 50 minutes of cordless operation.
Use the included USB cord to charge via a computer or adapter. A red light indicates charging progress.
Charge only as needed up to 12 hours. Do not overcharge. Disconnect when not in use. Device cannot be used while charging.
Ensure skin is perfectly clean and dry. Do not apply cream, body milk, or soap before shaving.
Fix shaving head, move shaver perpendicular to skin, stretch skin, and use slow movements with light pressure.
For underarms, move upwards. For bikini line, stretch skin and move from outside to inside.
After each use, pull up the shaving head, clean hair with a brush, then reattach the head and protective cover.
Ensure proper charging, taut skin, clean/dry skin, correct direction (against hair growth), and 70-degree angle.
Unplug appliances when not in use. Power is on if plug is inserted, regardless of switch position.
Avoid water, flames, aerosols. Not for use with anesthetics. Supervise children. Do not disassemble or incinerate.
Not a medical device. Consult doctor for skin conditions. Keep away from medical devices like pacemakers.
Two-year limited warranty against defects. Registration within 90 days required. See website for details.
The ZIVA Advanced Precision Rechargeable Lady Shaver is a cordless and rechargeable device designed for hair removal. It offers advanced precision and is suitable for various body areas, including legs, underarms, and the bikini line. The device is intended for dry use only and emphasizes gentle application for optimal results.
The ZIVA Lady Shaver's primary function is to remove unwanted body hair. It features a treatment head that works by gently shaving hair from the skin's surface. The device is designed to be used against the direction of hair growth to achieve a smooth finish. It is equipped with a dual switch ON/OFF button for easy operation. The ZIVA is a cordless device, allowing for freedom of movement during use, and is powered by a rechargeable NiMH battery, making it suitable for travel.
Before first use, the ZIVA device requires a full 12-hour charge, even if the charging indicator light changes color earlier. A full charge allows for up to 50 minutes of cordless operation. To charge, the included USB cord is inserted into the charging port on the ZIVA, and the USB end is connected to a computer's USB port or a USB wall adapter plugged into an electrical outlet. A tiny red light indicates that charging is in progress. It is crucial to allow the full 12-hour charging time to ensure optimal battery life and performance, and to avoid overcharging, which can shorten battery life. The device should be powered off and unplugged from the power source before use, as it cannot be used while charging.
For optimal hair removal, the skin must be perfectly clean, dry, and free from any creams, body milk, soap, or shaving cream before use. For legs, the shaving head should be fixed on the device, and the switch slid upwards to turn it on. The shaver should always be held perpendicular to the surface being shaved. It is recommended to work with both hands: stretching the skin taut with one hand and moving the appliance with the other. The shaver should be moved slowly with light pressure; pressing too hard can slow down the appliance and cause skin irritation. After shaving, it is advised not to apply any perfume or deodorant for 24 hours.
For sensitive areas like underarms, the device should be moved from the bottom in an upwards direction. For the bikini line, the skin should be carefully stretched, and the appliance moved from the outside to the inside. The ZIVA is specifically designed for dry use, and it is important to ensure the skin is clean and completely dry before each use. Users should avoid applying deodorants or alcohol-based lotions immediately before or after shaving, though baby powder may be used if desired.
To achieve the best results, proper shaving technique is essential. Users should pull their skin tight with one hand and slowly move the shaver along the skin, ensuring the shaving head or trimmer head is in full contact with the skin. The device should be held at a 70-degree angle to the skin and moved against the direction of hair growth. Avoiding excessive pressure is key to preventing skin irritation and ensuring efficient operation. Dirty or oily skin can cause irritation and hinder effective hair removal, so maintaining clean skin is paramount.
Proper care and cleaning are vital for the ZIVA lady shaver's reliability and longevity. After each use, the shaving head should be pulled up, and any hair on the shaver body should be cleaned with a brush. Once cleaned, the razor head should be put back in place, and the protective cover restored. This routine maintenance helps ensure the device remains hygienic and performs optimally for future uses. The device is designed to be durable, but proper handling and cleaning contribute significantly to its lifespan and effectiveness.
| Brand | Spa Sciences |
|---|---|
| Model | ZIVA |
| Category | Electric Shaver |
| Waterproof | Yes |
| Cordless | Yes |
| Floating Heads | Yes |
| LED Light | Yes |
| Power Source | Rechargeable battery |