EasyManua.ls Logo

Spartan Power SpartanStart - User Manual

Spartan Power SpartanStart
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPARTAN POWER • 895 E. PATRIOT BLVD., SUITE 103 • RENO, NV 89511 • (775) 800-1725 • SPARTANPOWER.COM
SpartanStart / Single Phase
RV AIR-CONDITIONING SOFT-STARTER
This model SpartanStart functions only as a soft-starter, a contactor or a relay is still required.
This model is designed to be used across a range of RV air-conditioning units. Unlike
commonplace designs, this soft-starter only requires access to the compressor’s three wires
(Run, Start and Common).
Parts List:
1 x SpartanStart Soft-starter
6 x Splice Connectors
1 x Alcohol Wipe
Warning:
1 This model does NOT electrically isolate the control box from the compressor. A suitable contactor or relay is necessary.
2 All voltage to equipment MUST be disconnected before removing any devices.
3 Allow 2 minutes to discharge run capacitor before disconnecting.
4 Do not swap the Run & Start Windings.
5 Poor crimping can lead to heating & subsequent damage to the soft starter.
Field Wiring Terminals (Applicable if wire harness is not provided):
Wire Range: 14 AWG Cu, stranded, for all terminals (Run Winding (R) and Active(T2))
Tightening Torque: 4.4 lbs-in [0.5 Nm] terminals.
Field wiring conductors shall be rated 167°F [75°C]
Suitable for use on a circuit capable of delivering no more than 5000rms symmetrical amperes, 120 volts maximum, when protected by a non-time
delay RK5 fuse or circuit breaker rated 80A, or a time delay fuse rated 70A. The device does not provide current limiting control or equivalent.
Spartan Start is NOT an overcurrent protection device and must NOT be used as a replacement for any primary circuit overcurrent protection.
LED Flash Codes:
LED Color Flash Code Status
1/3
Green
Red
ON
FAULT
Unit powered
Unit off
Under-voltage detected
Overload protection detected
On
Off
Rapid (3 sec)
Slow (1/2 sec)
WARNING:
This product can expose you to chemicals which are known to the State of California
Instruction Guide
Question and Answer IconNeed help?

Do you have a question about the Spartan Power SpartanStart and is the answer not in the manual?

Summary

SpartanStart Product Overview and Safety

Parts List

Lists the components included with the SpartanStart soft-starter kit.

General Safety Warnings

Provides crucial safety advice and operational precautions for using the soft-starter.

LED Flash Codes

Explains the meaning of LED colors and flash patterns for status indication.

Field Wiring and Circuit Specifications

Details technical requirements for field wiring and circuit protection.

California Proposition 65 Disclaimer

Notifies users about potential chemical exposure risks associated with the product.

Installation Procedure

Preparation and Component Identification

Steps for opening the unit, accessing wiring, and identifying wires.

Soft-starter Placement

Guidance on selecting suitable locations to mount the soft-starter.

Wiring Connections

Instructions for making secure electrical connections on both supply and compressor sides.

Final Assembly and Testing

Steps for securing the soft-starter, replacing covers, and verifying operation.

Spartan Power SpartanStart Specifications

General IconGeneral
BrandSpartan Power
ModelSpartanStart
CategoryController
LanguageEnglish