    How to make a packet capture on SpectraLink Server?
    • S
      Shannon HuangAug 12, 2025
      To create a packet capture from the web-based Administration Page of the SpectraLink IP-DECT Server: 1. Go to Status, then Packet Capture. 2. On the Packet Capture page, input the necessary filters. 3. Start the capture, reproduce the issue, stop the capture, and save the file.
  • A
    Andrew ThomasAug 17, 2025
    How to diagnose network issues on SpectraLink IP-DECT 400 Server?
    • B
      bwilliamsAug 17, 2025
      To diagnose network issues on the SpectraLink Server: 1. Navigate to Status, then Network Diagnose. 2. Enter the IP address or domain name under Host. 3. Click Ping to verify network connectivity. 4. Click Trace route to trace the route to the host.
  • R
    Rebecca WheelerAug 25, 2025
    Why do SpectraLink IP-DECT 400 base stations frequently lose synchronization?
    • E
      Evan CaseyAug 25, 2025
      The traffic between base stations might be delayed a varying amount of time because of traffic load, switch quality, or configuration. To resolve this, reconfigure or replace switches, or change the network topology to minimize the transmission time variance.
  • N
    Nicole MillerAug 30, 2025
    What to do if SpectraLink IP-DECT 400 synchronization fails after starting?
    • E
      Elizabeth MolinaAug 30, 2025
      If synchronization is initially okay but fails shortly after startup, it could be due to active IGMP snooping without an IGMP querier present to refresh multicast group memberships. The suggested solution is to add an IGMP querier to the network or disable IGMP snooping.
  • C
    Courtney KimSep 4, 2025
    How to fix if all SpectraLink Server base stations are synchronization masters?
    • T
      Timothy HoltSep 4, 2025
      If all base stations are synchronization masters, it indicates that multicast traffic is being blocked in the network. To resolve this, enable multicast traffic on all switches between the base stations.