118
Step Action Value(s) Yes No
8
Using a DVOM check for continuity be-
tween FRP sensor connector signal A
and sensor ground K2.
Do you have continuity?
Repair the
shorted to
ground sig-
nal circuit.
See wire
harness re-
pair section.
Go to Step
(9)
9
Using a DVOM check for continuity be-
tween FRP sensor connector B and
engine ground.
Do you have continuity?
Repair the
shorted to
ground sig-
nal circuit.
See wire
harness re-
pair section.
Go to Step
(10)
10
Inspect ECM connector and wire harness
connector terminals for corrosion, conta-
mination or mechanical damage.
Any problems found?
Repair har-
ness and
connector as
necessary.
See wire
harness re-
pair section.
Go to Step
(11)
11
Replace ECM.
Is the replacement complete?
Go to Step
(12)
12
Remove all test equipment except the
DST.
Connect any disconnected components,
fuses, etc.
Using the DST clear DTC information from
the ECM.
Turn the ignition OFF and wait 30
seconds.
Start the engine and operate the vehicle to
full operating temperature
Observe the MIL
Observe engine performance and drivea-
bility
Does the engine operate normally with no
stored codes?
System OK
Go to OBD
System
Check