195
Typical TPS and Throttle Position Readings (assumes 5.00 supply voltage):
Actual
Throttle
Position
TPS1
reading at
Throttle
TPS2
reading at
Throttle
TPS1
reading
on Moni-
tor
TPS2 reading
on Monitor
Throttle
Position on
Monitor
Fully
closed
0.32 4.70 0.32 0.30 0
¼ Open 1.32 3.70 1.32 1.30 25
¾ Open 3.32 1.70 3.32 3.30 75
Fully Open 4.32 0.70 4.32 4.30 100
CONDITIONS FOR SETTING THE DTC
A short circuit code will set if the TPS1 (as shown on the diagnostic monitor) is greater than 99.02%
of the 5 Volt Power Supply 1 (approx. 4.95 volts)
A short circuit code will set if the TPS2 (as shown on the diagnostic monitor) is greater than 99.8% of
the 5 Volt Power Supply 1 (approx. 4.99 volts)
An open circuit code will set if the TPS1 (as shown on the diagnostic monitor) is less than 4% of the 5
Volt Power Supply 1 (approx. 0.2 volts)
An open circuit code will set if the TPS2 (as shown on the diagnostic monitor) is less than 4% of the 5
Volt Power Supply 1 (approx. 0.2 volts)
Also see DTC 51.