95
Typical TPS and Throttle Position Readings (assumes 5.00 supply voltage):
Actual
Throttle
Position
TPS1
reading at
Throttle
TPS2
reading at
Throttle
TPS1
reading
on Moni-
tor
TPS2
reading
on Moni-
tor
Throttle
Position
on Moni-
tor
Fully
closed
0.32 4.70 0.32 0.30 0
¼ Open 1.32 3.70 1.32 1.30 25
¾ Open 3.32 1.70 3.32 3.30 75
Fully Open 4.32 0.70 4.32 4.30 100
CONDITIONS FOR SETTING THE DTC
DTC 51 will set if TPS1 and TPS2 disagree by greater than 5.96%
A short circuit code will set if the TPS1 (as shown on the diagnostic monitor) is greater than 99.02%
of the 5 Volt Power Supply 1 (approx. 4.95 volts)
A short circuit code will set if the TPS2 (as shown on the diagnostic monitor) is greater than 99.8% of
the 5 Volt Power Supply 1 (approx. 4.99 volts)
An open circuit code will set if the TPS1 (as shown on the diagnostic monitor) is less than 4% of the 5
Volt Power Supply 1 (approx. 0.2 volts)
An open circuit code will set if the TPS2 (as shown on the diagnostic monitor) is less than 4% of the 5
Volt Power Supply 1 (approx. 0.2 volts)