Failsafe
Failsafe position is set during binding. In the unlikely event that the radio link
is lost during use, the receiver will drive all channels to its pre-programmed
failsafe position.
SmartSafe
+
Hold Last
(AR6600T only)
If loss of signal occurs, SmartSafe
technology moves the throttle channel
to its preset failsafe position (low throttle)
that was set during binding. All other
channels hold their last position. When
the receiver detects signal from the
transmitter, normal aircraft operation
resumes.
Preset Failsafe
(AR6600T and AR6270T)
Preset failsafe is ideal for sailplanes,
allowing the aircraft to automatically
dethermalize if the signal is lost. With
preset failsafe, all channels go to their
preset failsafe positions if the signal
is lost, preventing a flyaway. When
the receiver detects signal from the
transmitter, normal aircraft operation
resumes.
SmartSafe
+
Hold Last
AR6600T AR6270T
1 Lower Throttle on transmitter NA
2 Push and Hold Bind Button NA
3 Power on Reciever NA
4
Release Button once RX goes into Bind
Mode (flashing LED)
NA
5
Place transmitter in Bind Mode and
finish Binding.
A* Install bind plug (optional) NA
B* Leave in through entire bind proccess** NA
Preset Failsafe
1
Move all sticks and switches on the
transmitter to desired Failsafe position.
Move all sticks and switches on the
transmitter to desired Failsafe position.
2 Push and Hold Bind Button Push and Hold Bind Button
3 Power on Reciever Power on Reciever
4
Release Button after RX goes into Bind
Mode (flashing LED)
Release Button after RX goes into Bind
Mode (flashing LED)
5
Push and Hold the Bind Button again
before the transmitter enters Bind Mode.
Place transmitter in Bind Mode and
finish Binding.
A* Install bind plug (optional) Install bind plug (optional)
B* Remove plug once RX goes into Bind Mode Leave in through entire bind proccess**
*Setting Failsafe can be done with the Bind Plug if desired.
**Remove Bind Plug when finished setting up Failsafe.
Tip: Use either the built in BIND button OR a bind blug in the BIND/BATT port.