OFF
FULL RATE
LOW RATE
WHO TO CONTACT
For service, please contact your authorised local Service agent giving full details of the
model, serial number and date of purchase
THIS UNIT IS SOLD AND SERVICED BY:-
DOMETIC PTY LTD
6 TREFOREST DRIVE
CLAYTON VICTORIA 3168
The appliance is fitted with the following injectors
Burners: 0.62mm 5.0MJ/h
Grill 0.62mm 5.0MJ/h
The burners on this appliance have fixed aeration and no adjustment is necessary.
DIMENSIONS
OPERATION
Ensure the gas cylinder is turned on.
In the event of a gas smell, turn off the cylinder and contact the supplier.
HOTPLATE BURNER
CAUTION: GLASS LIDS MAY SHATTER WHEN HEATED. TURN OFF ALL
BURNERS AND GRILL BEFORE SHUTTING THE LID.
Each burner is controlled individually and may be monitored by a flame supervision
device. In the event of the burner flames being accidentally extinguished, turn off the
burner control and do not attempt to re-ignite the burner for at least one minute. The
respective knob positions are show in Fig 1.
Fig 1.
BEFORE LEAVING
The pipe connections should be checked for leaks
with soap and water. DO NOT use a naked flame
for detecting leaks.
Test all burners on high and low flame for flame
stability. When satisfied with the appliance, please
instruct the user on the correct method of
operation. If the appliance fails to operate
correctly after all the checks have been made,
refer to the authorised service provider in your
area.