Pond & Waterfall Pumps
Instructions for Operation • Safety • Warranty
Designed for minimal solids applications
TLS1850 • TLS2750 • TLS4250
Thank you for purchasing the Spirit Pond & Stream pump from EasyPro. These pumps are designed for
continuous duty use in small ponds, statuary, Just-A-Falls, etc. A great choice for ponds with light debris
laden water.
Specications
• Canberuninverticalorhorizontalpositionsforcompactapplications
• Oil-lessdesign,shandplantsafe
• Impellerdesignedforpassingdebrisupto
1
/
4
" diameter
• 1
1
/
4
" female threaded outlet with a 1
1
/
4
" x 1
1
/
2
" elbow included
• Triplesealed115vmotorswith18monthwarranty
• Automaticoverloadandthermalprotectionwithselfreset
Run in vertical or horizontal position
Safety & Electrical Connections
1. Always disconnect the electricity supply before handling, maintaining,
repairing or installing any pond equipment.
2. Alwaysmakesureyouknowthecorrectampsandvoltagerequiredbeforeinstalling.
3. Usededicatedpoweroutletonly.Sharingtheoutletwithotherequipmentmaycauseoverheatingandre.
4. EasyProTLSpumpscomein115voltonly.
5. AlwaysconnecttoaGroundFaultCircuit(GFCI)topreventelectricalshock.Neversubmergeconnectingpowercablepluginwater.
6. Neverletthepumprunwithoutwaterasthiswilldamagetheimpeller,overheatandpossiblyburnoutthepump.Thispumpmust
staysubmergedentirelywhenopeating.Ifusedinaskimmer,thedebrisnetmustbekeptcleantoensureadequatewaterowto
pump.Runningpumplowonwaterwillcauseoverheating,prematurefailureandwillvoidwarranty.
7. Do not use this product in bathrooms or swimming pools. For use with fresh water only.
8. Donotletthewaterlevelinyourwaterfeaturefallbelowthetopofthepumpbody.
9. Allelectricalworkmustbeperformedbyaqualiedtechnician.AlwaysfollowtheNationalElectricalCode(NEC)ortheCanadianElectrical
Codeaswellasalllocal,stateandprovincialcodes.Codequestionsshouldbedirectedtoyourlocalelectricalinspector.Failureto
followelectricalcodesandOSHAsafetystandardsmayresultinpersonalinjuryorequipmentdamage.Failuretofollowmanufacturer’s
installationinstructionsmayresultinelectricalshock,rehazard,personalinjuryordeath,damagedequipment,provideunsatisfactory
performanceandmayvoidmanufacturer’swarranty.
10.Donotattempttodisassemblepumpduringthewarrantyperiod.IfthereareanyquestionspleasecontactyourlocalEasyProdealer.
11. Neveruseanextensioncordortamperwithpowercord.Powercordcannotbecomebent,twisted,abradedorcut.Adamgedcablemay
causeelectricleakage,shockorre.
12. Themotorhasabuilt-inprotectionsystemwhichstopsthepumpwhenoverheatingoccursduetoexcessiveloadorlowwater,thiscanbe
causedbycloggingatinlet/outletorwhenucuationsoccurinpowersupply.Thecoolingtimeisroughly15to20minutes,thenthepump
willautomaticallycomebackon.Iftheoverloadistripped,itisessentialtoidentifyandremedythecauseoftheoverheating.
Installation
• Donotpaintcasing,overheatingmayoccur
• Liftonlybyhandle,notbypowercableoroatswitch
• Donothangpumpinwater,installonsolidatbaseinuprightorhorizontalposition
• Installproperoutletadapterforpipeorhose
• Makesurethatpowercableplugandpoweroutletareawayfromwaterandwaterdischargepipe/hose.
Question and Answer IconNeed help?

Do you have a question about the Spirit TLS1850 and is the answer not in the manual?

Spirit TLS1850 Specifications

General IconGeneral
BrandSpirit
ModelTLS1850
CategoryWater Pump
LanguageEnglish

Summary

Safety and Electrical Guidelines

Disconnect Power Before Servicing

Always disconnect electricity supply before handling, maintaining, repairing, or installing pond equipment.

Verify Electrical Requirements

Always ensure you know the correct amps and voltage required before installing the pump.

Dedicated Power Outlet Usage

Use a dedicated power outlet only to prevent overheating and fire risk from shared outlets.

GFCI and Water Safety

Always connect to a GFCI and never submerge the power cable plug in water for shock prevention.

Prevent Dry Running and Submersion

Never let the pump run without water; it must stay submerged to prevent overheating and failure.

Water Feature Compatibility

Product is for fresh water only; do not use in bathrooms or swimming pools.

Electrical Code and Professional Installation

All electrical work must be performed by a qualified technician following all applicable codes.

Extension Cord and Power Cord Restrictions

Never use extension cords; power cords must not be bent, twisted, abraded, or cut.

Motor Protection System

Motor has protection against overheating due to load or low water, with auto-reset after cooling.

Pump Operation Guidelines

Safe Operation Environment

Do not start operation with people standing near intake or outlet; never operate out of water.

Water and Solids Compatibility

Use only for circulation of water with limited solids up to 1/4"; do not pump oil or chemicals.

Prevent Clogging and Damage

Do not allow foreign objects to clog intake; turn off power during outage to prevent restart damage.

Service and Maintenance Procedures

Disconnect Power for Service

Disconnect all power supplies before inspection or service to avoid possible electrical shock.

Regular Cleaning and Inspection

Remove, clean, and check pump for damage regularly to prolong its life and maintain flow.

Winterization and Storage

Wash and dry pump, store indoors in non-freezing location; prevent freezing if left in water.

Troubleshooting Common Issues

Pump Does Not Start

Check power cord connection, float movement, circuit breaker, and pump cord contact.

Pump Humming or Running with No Water

Check for clogged suction, worn impeller, high head, or low water level.

GFCI Breaker Tripping

May indicate damaged power cord, improper grounding, or overloaded circuit.

Motor Briefly Starts and Stops

Check for low water conditions, pump overheating, clogged inlet/impeller, or improper power supply.

Pump Stops Unexpectedly

Check water density, clear impeller obstructions, verify power supply, or wait for cooling.

Product Specifications and Performance

Performance Curve Data

Graph showing pump head (ft) versus capacity (GPM) for different models.

Model Performance Table

Details maximum GPH, HP, Watts, and Head for TLS1850, TLS2750, and TLS4250 models.

EasyPro Pond Products Limited Warranty

Warranty Coverage and Period

18-month warranty against mechanical/material defects for properly installed products from authorized sellers.

Exclusions and Limitations

Warranty excludes accidental damage, normal wear, improper use, or modifications.

Making a Warranty Claim

Obtain RA number, include original receipt, and pay return shipping charges for claims.

Liability Limitations

EasyPro not liable for consequential damages, loss of livestock, or other indirect losses.