TROUBLESHOOTINGGUIDE
FAULT
CAUSE REMEDY
ElectricitySupplyisfaulty Checkthepowerplugispluggedin.
Iffitted:
‐Thermostatsettingisincorrect
‐Thermostatplugisnotpluggedin
‐Thermostat/thermostatconnectionsislooseorfaulty
∙Checkthatthefueltankisfull.Fillifnecessary.
∙Checkfuelfilterforblockages.Cleanandreplaceas
necess ary.
∙Check
fuellineforblockages.Cl eanandreplaceas
necess ary.
∙Checkairlineforblockagesorleaks.Tighten,clean
andreplaceasnecessary.
∙Checkairfilters.Cleanandreplaceasnecessary
Inlet/outletgrillorinsideofheaterisdirtyorpartiallyblocked ∙Checkandcleanasnecessary
Fueliscontaminatedorpoorquality ∙
Draintankandreplacefuel
∙Checkandadjustandcleancompressorregulating
valveasnecessary
(Followprocedurelistedinthemaintenance
instructions)
∙Checkairlineforblockagesorleaks.Tighten,clean
orreplaceasnecessary.
D Allother ContactyourAuthorisedDealer
CheckThermostatsettingandconnections
Dieselflowabs entorlow
C Heater
runs but
excessive
smokeorsmell
isemitted
Pressureadjustme ntisincorrect
Thefanmotor
neverstarts
A
B Thefanmotor
startsbutunit
goesinto
lockout