EasyManua.ls Logo

S+S Regeltechnik THERMASGARD RTM1 User Manual

Default Icon
32 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
THERMASGARD
® 
RTM 1- Modbus
D G F r
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l’acquisition d’un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
D
Bedienungs- und Montageanleitung
Raumbedien-Temperaturfühler (± 3 %), Aufputz,
für Temperatur, relative Feuchte, Taupunkt,
kalibrierfähig, mit
Modbus
-Anschluss
G
Operating Instructions, Mounting & Installation
Room operating temperature sensor (± 3 %),
on-wall, for temperature, relative humidity, dew point,
calibratable, with
Modbus
connection
F
Notice d’instruction
Sonde de température ambiante (± 3 %),
en saillie, pour température, humidité relative,
point de rosée, étalonnable, avec raccordement
Modbus
r
Руководство по монтажу и обслуживанию
Датчик температуры в помещении (± 3 %), для открытой
установки, для температуры, относительной влажности,
точки росы, калибруемый, с возможностью подключения к
шине Modbus
6003-2400-2015-000 32400-2016 V100 11 ⁄ 2015
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG GERMANY
FON +49 (0) 911 5 19 47- 0
FAX +49 (0) 911 5 19 47- 70
mail@SplusS.de
www.SplusS.de
Question and Answer IconNeed help?

Do you have a question about the S+S Regeltechnik THERMASGARD RTM1 and is the answer not in the manual?

S+S Regeltechnik THERMASGARD RTM1 Specifications

General IconGeneral
Enclosure protection classIP65
Protection classII
MountingWall mounting
SensorPT1000
TypeRoom thermostat
Temperature range-35...+35°C

Summary

Operating Instructions, Mounting & Installation

Dimensional Drawing

Technical Data

Voltage Supply

Specifies the power supply requirements for the device.

Power Consumption

Details the power draw of the device under different conditions.

Sensor Specifications

Describes the integrated temperature and humidity sensor capabilities.

Measuring Range

Outlines the operational temperature measurement limits.

Temperature Deviation

Specifies the accuracy tolerance for temperature measurements.

Installation Options

Describes how and where the device can be mounted.

Schematic Diagram

DIP Switch A Configuration

Explains how to set the Modbus bus address using DIP switches.

DIP Switch B Configuration

Explains how to set Modbus bus parameters like baud rate.

Offset Correction

Details how to adjust the temperature offset using potentiometers.

Configuration

Bus Address Setting

Explains how to set the Modbus device address using binary coded DIP switches.

Bus Parameters Configuration

Details the configuration of baud rate, parity, and bus termination.

Communication Indicator

Explains the meaning of the device's LEDs for communication status.

Diagnostics

Mentions the integrated error diagnostic function.

Display Configuration and Readout

Segment Pattern Configuration

Details how to control individual segments of the display using registers.

14-Segment Pattern Configuration

Explains how to program the 14-segment display areas with characters.

Telegrams and Display Configuration

ASCII Code Table for Dot Matrix

Provides the ASCII mapping for characters displayed on the dot matrix area.

Modbus Write Registers

Details Modbus registers for configuring device parameters and display.

Telegrams and Data Reading

Modbus Read Input Registers

Lists Modbus registers for reading temperature, dew point, and humidity values.

Modbus Diagnostics Function

Explains sub-functions for device diagnostics and error reporting.

Modbus Report Slave ID Function

Details the telegram structure for reporting the slave device identity and version.

Installation and Bus Structure

General Modbus Bus Structure Layout

Illustrates common Modbus RTU network configurations and topologies.

Bus Topology with Termination

Explains the electrical setup of the Modbus bus with resistors.

Bus Line Termination and Bias Resistors

Details the rules for installing terminating and bias resistors on the Modbus bus.

Mounting and Installation Guidelines

Mechanical Mounting and Attachment Notes

Offers important considerations for physical mounting and environmental factors.

Important Notes and Safety Precautions

Covers general terms, safety, intended use, and warranty disclaimers.

Enclosure Opening Procedure

Bus Address Mapping

Related product manuals