EasyManua.ls Logo

SPX Cooling Tower Marley NC Class User Manual

SPX Cooling Tower Marley NC Class
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Q u i e t B y D e s i g n
/
Marley NC
®
Class Cooling Tower
/
>ViÊ
N
Ê>ÊÀÞÊ}Ê
N
Ê>ÀiÞ
}Ê/iV}iÃ
Question and Answer IconNeed help?

Do you have a question about the SPX Cooling Tower Marley NC Class and is the answer not in the manual?

SPX Cooling Tower Marley NC Class Specifications

General IconGeneral
BrandSPX
ModelCooling Tower Marley NC Class
CategoryFreezer
LanguageEnglish

Summary

The Result of Sound Engineering

NC Class Performance Benchmarks

NC Class sets benchmarks for low sound, high crossflow tonnage densities, thermal performance, and value.

Product Development Process

NC Class evolution utilized SPX's ISO 9001 Certified Product Development Process.

Proven Design Guaranteed Performance

Long Life Construction

Available in stainless steel or galvanized steel, with a 5-year limited warranty on stainless steel towers.

Low Operating Costs

Achieved through high-efficiency fill, fans, gravity-flow water distribution, and efficient mechanical drive systems.

All Season Performance

Operates efficiently in summer heat, spring/fall energy management, and virtually ice-free in winter.

Real World Design

Designed for severe wind, seismic, shipping, operating, and live loads.

CTI Certified

Guarantees thermal performance of each tower as installed.

Factory Mutual Approved

FM approval available on the entire line of NC Class cooling towers at no additional cost.

NC Feature Highlights

Air Movement Package

Details on fan guards, inlet cylinders, high-efficiency fans, Marley Geareducer, PowerBelt drive, and TEFC motors.

Water Distribution System

Options for piping connections, gravity flow distribution, spiral target nozzles, PVC film fill, and drift eliminators.

Structure

Covers crossflow configuration, stainless steel or galvanized steel construction, factory assembly, and access doors.

Mechanically Correct Quiet by Design

High Efficiency Axial Fan

Adjustable-pitch fan blades for maximum horsepower utilization and field adjustments.

System 5 Geareducer

Requires no oil changes for five years, offering low maintenance and reduced environmental impact.

Fan Motor

TEFC 1.15 service factor, horizontal-shaft motor designed for cooling tower duty and humid service.

SofTork Coupling

Absorbs excessive shock loads at start-up and forgives minor misalignment.

Five-Year Mechanical Warranty

Covers total mechanical equipment and includes a 5-year maintenance-free System 5 Geareducer.

Popular Options

Inlet Connection Options

Choose from single side inlet or bottom inlet connections for piping.

Access and Safety Features

Includes handrail, ladder, ladder safety cages, and access door platforms for maintenance.

Motor Location Options

Option for outside motor location to avoid tower plenum humidity, using a stainless steel driveshaft.

Distribution Basin Dam

Manages flow rates and protects the tower from water distribution issues like icing or scaling.

Control and Water Systems

Features control systems, variable speed drives, and solid state water level control packages.

Collection and Distribution Basins

Offers stainless steel basins for corrosion resistance and longevity.

Air Inlet Screens

Galvanized wire mesh screens to keep leaves and debris out of the air inlets.

The Marley Difference

Technical Reference Manual

Manual provides engineering schematics, data, and layout information for tower installation.

Product Specifications

Details SPEC SSNC (stainless steel) and SPEC NC (galvanized) for specification language and information.