011 WWW.STUPIDSIMPLE.TOOLSSST003
Operations & Maintenance
Maintenance
SST00304
DRAIN STAGE 1 & STAGE 2 CANISTERS
Interval: Daily
Operation: Push in drain pins to drain collected condensate and fluids from the
canisters
READ FILTER HEALTH INDICATOR
Interval: Weekly
Operation: Observe the indicator when pressure is applied - any red shown indicates a
loss of coalescing filtering capability. A fully red indicator would indicate a completely
clogged and exhausted filter, requiring immediate replacement.
CLEAN STAGE 3 STAINLESS FILTERS
Interval: Annually
Operation: Remove the top and bottom stainless filters from the MEGAFLOW assembly,
and blow them clean of any desiccant particles using compressed air.
SERVICE FILTER ELEMENTS
Interval: At a minimum, per stage
Stage 1: 6 months - 1 year
Stage 2: 6 months - 1 year
Stage 3: 1 month - 6 months