EasyManua.ls Logo

SST MEGAFLOW - Routine Maintenance and Service Intervals

SST MEGAFLOW
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
011 WWW.STUPIDSIMPLE.TOOLSSST003
Operations & Maintenance
Maintenance
SST00304
DRAIN STAGE 1 & STAGE 2 CANISTERS
Interval: Daily
Operation: Push in drain pins to drain collected condensate and fluids from the
canisters
READ FILTER HEALTH INDICATOR
Interval: Weekly
Operation: Observe the indicator when pressure is applied - any red shown indicates a
loss of coalescing filtering capability. A fully red indicator would indicate a completely
clogged and exhausted filter, requiring immediate replacement.
CLEAN STAGE 3 STAINLESS FILTERS
Interval: Annually
Operation: Remove the top and bottom stainless filters from the MEGAFLOW assembly,
and blow them clean of any desiccant particles using compressed air.
SERVICE FILTER ELEMENTS
Interval: At a minimum, per stage
Stage 1: 6 months - 1 year
Stage 2: 6 months - 1 year
Stage 3: 1 month - 6 months