ST7735R
V0.2 111 2009-08-05
10.1.25 TEOFF (34h): Tearing Effect Line OFF
34H TEOFF (Tearing Effect Line OFF)
Inst / Para D/CX
WRX
RDX
D17-8
D7 D6 D5 D4 D3 D2 D1 D0 HEX
TEOFF 0 1 - 0 0 1 1 0 1 0 0 (34h)
Parameter No Parameter -
Description
-This command is used to turn OFF (Active Low) the Tearing Effect output signal from the TE signal line.
Default
Status Default Value
Power On Sequence OFF
S/W Reset OFF
H/W Reset OFF
Flow Chart
TE Line Output
ON
TEOFF
TE Line Output
OFF
Command
Parameter
Display
Action
Mode
Legend