EasyManuals Logo

Stafford Instruments ST315 User Manual

Stafford Instruments ST315
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Page ST315 User Handbook
4
Contents
Contents
At A Glance.................................................. 2
Quick Start Guide......................................... 3
Contents........................................................ 4
Features ........................................................4
Turning On...................................................5
Programming................................................ 6
Firing ............................................................ 9
Cooling....................................................... 13
Adjusting While Firing............................... 14
Error Messages........................................... 16
Other Features ............................................ 18
9 programs each with up to 9 segments
1 controlled heating / cooling ramp + soak per segment
Soak times up to 99 hours 59 mins
Ramp rates from 1 to 999°C/hour + full
Ideal for glass or ceramics use
Programs can be altered while firing
Program pause/un-pause + segment advance facilities
Keyboard lockable
Delayed start facility - up to 99 hours 59 mins
Power failure recovery
Energy used display
Alarm buzzer & optional alarm output
Features
Features
ST315 User Handbook Page
17
All error messages cause the ST315 to terminate the firing with all the
keys locked. An alarm buzzer sounds once per second.
SWITCH KILN OFF!
To reset the ST315 turn off the power to the instrument and have the fault
investigated by your installer or kiln service engineer to rectify the fault.
Technical note: any error message will cause the auxiliary alarm relay
(if fitted) to open—see installation handbook for details.
Note: these error messages are provided to detect kiln faults and so offer
some protection to the kiln. For increased protection the use of a heat fuse
or other independent over-temperature trip is recommended—such as the
Stafford Instruments ST101.
Error 7. Maximum room temperature
exceeded. The internal temperature of the
ST315 has exceeded an installer
selectable (30—70°C) limit.
Err7
°C
°C/hr
hr.min
Possible causes are: room vent fan failure, ventilation grills blocked, kiln room
too small, damper or bung left open