ph1
ph2
st3
ph3
white motor
1 and
motor
2
brown
motor
1 and
motor
2
GB
electric
lock
open gate detector
(SCA)
+
-
+
-
24V
WARNING: Connect the
encoder to the board
keeping
to the
colours
of
LINE
L N
24V
5W
0.5A
12V
10W
the cables
as shown
+
-
T
1,25A
common
start stop
photocell
in
closing
mot1
mot2
common
pedestrian
photocell
in
opening
and
in
closing
24V
25W
flasher
0
230
TRASFORMER
24
0
The current feed line (230V L,N, ) to the
automation
must be
protected
by a ma-
gnetometric
switch or a pair of 5A fuses. A
differential
switch is
recommended
but not
neccessary
if it is already
found
at
the
top of
the
system.
Feed
the
device with a
3x1,5mm
2
cable
(phase+neutral+ground).
If
the distance
betwe-
en the
board and
the connection
to
the grounding system exceeds
30m it is
necessary
to
provide
an
earth plate near the control
board.
Cabling must
be
done when the control
board is
switched
off.
Input
of N.C. type
contacts (normally closed),
if
they
are
not used, must
be bridged with
an ordinary terminal (+24V). If there are more
N.C.
contacts for the same input they
must
be placed in
series (example:
ph1 and ph2 in
the
diagram).
Inputs
of N.O. type
contacts (normally
open), if not used,
must
be
left
free. If
there
are
more
N.O.
contacts for the same input they must
be
placed
in
parallel (example:
st1 and
st2 in
the
diagram).