GB
Operating procedure
at
the
first start up
•Undertake
the electric wiring for the plant and
check
when the
card is
switched
off.
•Check that the mechanical stops have been instal-
led
correctly
and
that the
wiring of
the
two motors
display
with
the
respective
encoders
has
been
done.
•Unblock the gate
and
check its movement (the hin-
ged leaves
must
have no obstacles in their path).
The stroke of the leaves must not have any stiff
points during movement,
it
must
be smooth.
LED
indicator for
E
power supply
•Block
the
gate and supply
current
to
the control
board. At
this point the
electric
mains detection
led will light up and the display will show r
00
or f
00
.
If this
does
not
occur check
that the control
board
receives
power and check
the
inputs
activated (see the description
of
the diagnostics
on
the
display).
•Activate the safety devices one at a
time
and check
that
the display shows the
relative diagnostics
wording. For
example, activate the photocell
and check that
the message
pho
shows
on
the
display.
Enter the menu
and
select the item
setup.
The first
two
manoeuvres help to
identify
the
start
and end of the
stroke
of the
motor.
The two
that
follow
detect
the peak
of
absorption
of
the motors when the
gate is
closing
and opening. In
this
phase,
monitor the values shown
on
the
display.
•At the end of the
learning
phase the display will show ok if
programming
was
done
correctly,
or err if
errors
occurred. To exit the
programme
press the select
key.
•Correctly set the levels of
anti-crushing
force in opening and in closing, these
must
be
greater than the maximum values
viewed
during
learning.
WARNING: this
regulation
can
influence
the degree of safety of an
automated
device.
During learning
manoeuvres
the control board ignores the START and PEDE-
STRIAN
commands
and
works with the force parameters that have been
set. Even
if
the safeties remain
active
make sure that there
are no objects or people in the
pathway of
the
gate.
•Carry
out some test
cycles
checking the correct operation
of
the entire
system.
•Measure the
force of
impact
of
the
gate according to
the specifications
of
regu-
lation
EN12445.
N.B: If a
blackout
occours while the
automation
is working, the
first
START com-
mand given
to
the control
board with power
supply
back, will close
the gate
until
the
board
finds the stops. Let the motor finish
its
run before
giving
other comman-
ds.