26
GB
WARNING:
check
that the
lock
catches without creating friction
and
regulate
the
parameter
tser accordingly.
fend
(end force
thrust
on
striking)
=
this is the force that the
motors
exercise in
closing once the limit stop
strikers
are reached. This is stated in percentages
compared
with the
maximum
force
that
the
motors themselves
can exercise. The
default value set
by
Stagnoli
is 30 and it can be
regulated from
20 to 70.
WARNING: regulate
fend
with
a low
value should the gate structure
be very light.
The
regulation
of this
parameter
can
influence the time
and force with which the
gate
works
in
the nal phase
of
the
stroke.
Functions
ca
(automatic
closing)
=
automatic closing
of
the
gate
after
it has
opened
fully.
ca=0
function not
enabled.
ca=1
function
enabled.
Set
the
ttca
regulation
to
customise the time that must
pass
from the
end of ope-
ning to
the start
of
automatic
closing. N.B: If
ca=1
and
2p=0
,
a START command,
activated while the leaves
are
opening,
will
stop the gate
and load
the
ttca time
for
automatic
closing.
ba
(impulse
block
during
opening)
=
the control
board
ignores the
START
impul-
ses
during the opening
phase.
ba=0
function not
enabled.
ba=1
function
enabled.
bp
(blocks impulses
during
pause)
=
the
control
board
ignores
the START
impul-
ses
during the pause between opening
and
automatic closing (
ca=1
).
Each START
command
received during the pause between opening and
automatic
closing
recharges the
ttca time.
bp=0
function not
enabled.
bp=1
function
enabled.
These functions allow the gate not to block
or
reverse the stroke due to other
START
commands,
in
condominium use
for example.
cr (rapid
closing)
=
if
there
is a passage
through
the
photocells during
the ope-
ning phase or with
the
gate open,
the regulation time
ttca (if
activated
and gre-
ater than
3 secs) is
automatically reduced
to 3 secs.
cr=0
function not
enabled.
cr=1
function
enabled.
2p
(open/close
operation)
=
2p=1
function enabled:
at each START
impulse,
the
movement
of
the
gate
changes direction
(OPENING
-
CLOSING).
2p=0
function
not enabled. the gate
movement sequence becomes
OPENING
-
CLOSING (
ttca)
-
CLOSING
-
STOP.
pl
(preflashing)
=
after the
START
signal, the asher
or
courtesy light activates
for
two
seconds before the opening
or
closing phase
begins.
pl=0
function not
enabled.
pl=1
function
enabled.