27
GB
sv
(suction
lock)
=
activating this function,
at
the start
of
the opening
manoeuvre,
a 12V
suction
lock is
controlled after
an
activation time regulated
by
the parame-
ter
tser.
sv=0
function not enabled (the
exit is
activated
only for
the
tser time).
sv=1
function enabled (the
exit
remains
active and
deactivates
only for
the
tser
time).
ar
(ramming
on
opening)
=
before starting the opening manoeuvre, motor
1
pu-
shes the
door in
closing
for two
seconds, allowing the electric
lock to
move
away
from the fastener.
At
this point, the
lock is
activated
and
the manoeuvre continues
its
normal opening
movement.
ar=0
function not
enabled.
ar=1
function
enabled.
re
(energy saving)
=
keeps
the photocells
off while
the system
is
not
active,
per
-
mitting energy saving. The photocells therefore remain active only while the
leaves
are in
movement
and
during
ttca
.
re=0
function not
enabled.
re=1
function
enabled.
Connect the current
feed
+/-24V
of both
the transmitter
and
receiver
of
the pho-
tocells
at
asher
exit.
1m
(one motor)= operation
of
the system
only with
motor
1.
1m=0
function not
enabled.
1m=1
function
enabled.
en
(encoder
operation)
=
allows the system
to
operate
also if
there
is an encoder
malfunction
(the gate blocks
shortly
after the
start
of
movement
and the display
shows
ENC1
or
ENC2
).
en=0
encoder not
enabled.
en=1
encoder
enabled.
WARNING: the
operation
of the
system without
encoder is to be
considered
as
being an
emergency
operation. In
this mode
every
obstacle encountered
by the
motors
will
make
it
stop.
When
the encoder
is
active instead, operating with
it=0,
each
obstacle encountered
by
the motors commands
an
reversal
of
movement
by
approximately
30cm.
ss
(soft
star
t)
=
allows
the motor
to
undertake
a
soft start
and at
reduced
speed
to
diminish stress
of the
mechanical
parts of the
system.
Activating this function,
the motors deliver less
power in
the starting
phase.
ss=0
function not
enabled.
ss=1
function
enabled.
oc
(open/close
function)
=
lthe START
terminal
input becomes OPEN and the
PEDESTRIAN
terminal
input becomes CLOSE. In this mode, one control opens
the gate and
another
closes it
without intermediate
stops. The PEDESTRIAN and
START
functions
can be activated with the radio
control
on the rst and second
channels
respectively.
oc=0
function not
enabled.
oc=1
function
enabled.