EasyManua.ls Logo

Stagnoli E24 - System Diagnostics and Reset Procedures; Alarm, Test, and Receiver Settings; Resetting Parameters and Erasing Transmitters

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
GB
•
it (total
reversal)
=
activating this
function,
if the
motors encounter
an obstacle
in the
opening
phase, they
reverse
the
motion
and close the gate
completely.
In
the closing phase, if they
encounter
an
obstacle,
the
movement
is
reversed
and
the
gate
opens completely.
If
the function
has
not been activated,
in
the
opening
phase, the motors stop
if
they encounter obstacles while
in
the closing phase
they
reverse motion
by 30cm
before
stopping.
it=0
function not
enabled.
it=1
function
enabled.
•
2b
(two safety
ribs)
=
Operates
with two
safety
ribs 8k2
connected
in parallel.
2b=0
function not
enabled.
2b=1
function
enabled.
•cf
(operation
of the fixed code
integrated receiver)
=
cf=0 receiver works with
rolling
codes.
cf=1
receiver works
with fixed codes.
Functioning
with receiver fixed codes or rolling codes can also be seen on the
initial
page of
the
display,
where
r-00
indicates the rolling
code
functioning
and
f-00
functioning
with fixed code.
The receiver can
memorise rolling
codes type HCS300 STAGNOLI with billions
of
combinations
or fixed codes type HT53200 with 13 bits or
the
fixed
part
of a
rolling
code (28 bit SN).
•
al
(alar
m)
=
Alarm signalling that the gate has remained open. This function
activates the
SCA
output after
20
seconds
have passed
from the
end of
the
time
regulated
by ttca and
the
gate is
still
open.
al=0
function not
enabled.
al=1
function
enabled.
•te
(test)=
A
diagnostics test
is carried out to check the
integrity
of the encoder
and
amperometric sensors before
each
time the motors
are started.
te=0
function not
enabled.
te=1
function
enabled.
Cancel
•
default parameter
=
to
cancel the regulation parameters
and
those
of regulated
functions
and
reset the factory settings, enter the menu
cancel, go to
default
pa-
rameter
on
the
display and press ENTER.
The message
RESE
is
shown,
it flashes
until the
decision to
reset
all
the parameters
is
confirmed
or
the operation
is can-
celled. The default parameters are:
ttca=10, aped=70, sfaa=1, sfac=3, rlap=20,
rlch=20,
sbat=5, v
rl=3, fm1a=50, fm1c=50, fm2a=50, fm2c=50,
tser=2,
fend=30, ca=1, ba=0, bp=0, cr=0, 2p=0, pl=0, sv=0, ar=0, re=0,
1m=0, en=1,
ss=0, ac=0, it=0, 2b=0, cf=0, al=0, te=0.
•
erase
1
transmitter
=
to cancel a
transmitter
code,
enter the menu
delete
,
then
go to the wording
erase
1
transmitter
on the display and press ENTER. The
message
PREMI.
(PRESS) will
appear.
Now
press the
key of
the transmitter that
must
be
cancelled.
If
the operation
has
been
carried
out correctly, the message
OK
will
appear. If
this
has
not been
carried
put correctly, the message
ERR
will appear.