GB
16
7.
Press the key to adjust the Y-axis up. Press the key
to adjust the Y-axis down. Figure Ⓜ illustrates how and
affect each axis.
NOTE: Holding or down slopes the axis
continuously. The rate of slope change increases over time.
Pressing or once adjusts the slope by 0.01°.
8.
The X/Y Select LED will ash RED when the
maximum slope angle is reached. The axis will not move
any further in he Y direction.
9.
Press the key again to set the Y-axis. The X/Y Select
LED turns off.
10.
The X-axis and Y-axis are now set to manually adjusted
slopes. Use the laser in Manual Slope Mode.
11.
To turn Manual Slope Mode OFF, press and hold for ≥ 2
seconds. When Manual Mode is turned OFF, the
LED stops ashing and the laser tool begins Auto-Levelling.
NOTE: To change between horizontal and vertical positions
the laser tool must be powered OFF, repositioned, and then
powered ON in the new position.
Changing the Rotation Speed
Press the Rotation Speed Key to cycle through the available
speed settings from fastest to slowest to Spot.
Available Speeds
RPM: 600 300 150 0 (Spot)
Using Spot Mode
Spot mode halts the rotary laser's rotation and allows the user to
manually adjust the angle of the "Spot".
1.
Use the key to cycle to the Spot setting (0 RPM).
2.
Use the key to rotate the Spot counterclockwise. Use
the key to rotate the Spot clockwise.
NOTE: Holding down the key or the key will rotate
the Spot continuously. After holding down an arrow key for
several seconds, the Spot ashes 3 times and then rotates
at a faster rate. A single press of an arrow key will rotate the
spot 0.5°.
Figure Ⓝ illustrates how the arrow keys affect the Spot
rotation.
Using Scan Mode
RL 700L and RL 750L-G
Scan Mode limits the rotary laser's projection to a set scan angle
and allows the user to manually adjust the position of the scan.
1.
Press the key to cycle through the available Scan angles
(10°/45°/90°).
2.
Use the key to rotate the Scan counterclockwise. Use
the key to rotate the Scan clockwise.
NOTE: Holding down the key or the key will rotate
the Scan continuously. After holding down an Arrow Key for
several seconds, the Scan ashes 3 times and then rotates
at a faster rate. A single press of an Arrow Key will rotate the
Scan 2.0°.
Figure Ⓝ illustrates how the arrow keys affect the Scan
rotation.
3.
Press the key to turn off Scan Mode and return to the
last used speed setting.
Using the Remote Control
RL 600L, RL 700L, and RL 750L-G
All available functions and modes are accessible through the
keys on the Remote Control with the exception of toggling the
Tilt Warning ON/OFF and powering ON the laser tool. (The laser
tool can be powered off.)
Using the Detector
The Detector allows the user to determine the location of the
laser when distance or lighting conditions make the laser difcult
to see.
Detector Keypad
Power ON/OFF Key
High/Low Accuracy Key
Speaker Volume Key