60
STHT77342
61
STHT77342
Niveau/punkt overførsel
 

 
 
 


 

 

Nøjagtighedscheck og
kalibrering
BEMÆRK:
 

 

 

 



• Låsen skal være i oplåst position for at tillade
at laserværktøjet autonivellerer inden check af
nøjagtighed.
Op og ned lodret
strålenøjagtighed
(Se illustration
M
)

M
1


1

2

1

2

M
2


1

2

2


3

M
3

3

3

1
 
3
• Hvis D
3
ikke er mindre end eller lig med kalkuleret
maksimale offset afstand skal værktøjet returneres
til Stanley forhandleren for kalibrering.
Maksimale offset afstand (SPL3):
= (D
1
m x 0,6
mm
m
) + (D
2
m x 1,2
mm
m
)
Maksimal
= D
1
ft x 0,0072
in
ft
) + (D
2
ft x 0,0144
in
ft
)
Sammenlign: (se illustration
M
3
)
D
3
≤ Maksimal
Eksempel:
• D
1
= 3m,D
2
= 1m,D
3
= 1,5mm
• (3m x 0,6
mm
m
) + (1m x 1,2
mm
m
) = 3,0mm
(maksimale offset afstand)
• 1,5mm ≤ 3,0mm(SAND, værktøj er indenfor
kalibrering)
Strålenøjagtighed for niveau
(Enkeltstråle) - (se illustration
N
)

N
1


1


N
2

2



N
3


3

2

N
4

4



N
5



4

1
• Hvis målingen er større end maksimale offsetafstand
skal værktøjet returneres til Stanley forhandleren
for kalibrering.
Maksimale offset afstand:
= 0,2
mm
m
xD
1
m-(2 x D
2
m))
Maksimal
= 0,0024
in
ft
x (D
1
ft-(2 x D
2
ft))
Sammenlign: (se illustration
N
5
)
D
3
-D
4
≤ ±maksimum
Eksempel:
• D
1
= 10m,D
2
= 0,5m
• D
3
= 0,4mm
• D
4
= -0,6mm
• 0,2
mm
m
x (10m-(2 x 0,5m) = 1,8mm(maksimal
offset afstand)
• (0,4mm)-(-0,6mm) = 1,0mm
• 1,0mm ≤ 1,8mm(SAND, værktøj er indenfor
kalibrering)