Table 1- ESD Control Program eTchnical Requirements Summary
(See paragraph 6.2 for further guidance regarding alternate test methods.)
Technical
Requirement
Reference
Paragraph
Implementing Process
or Method
Area
1
Mfg.
Area
2
Field
Test Method,
Standard or
Advisory
Recommended
Range
5
Grounding /
Bonding
Systems
6.2.1
ANSI EOS/
ESD S 6.1
Equipment Ground
R
O
ANSI EOS/
ESD S 6.1
< 1.0 ohm
AC Impedance
Auxiliary Ground
O
O
ANSI EOS/
ESD S 6.1
< 1.0 ohm
AC Impedance
Equipotential Bonding
O
O
ESD ADV 2.0
< 1.0 X 10
9
ohm
6
Common Point Ground
R
O
ANSI EOS/
ESD S 6.1
< 1.0 ohm
AC Impedance
Personnel
Ground
6.2.2
Wrist Strap System
ESD S 1.1
< 35 X 10
6
ohm
7
Seated Operations
R
R
Standing Operations
O
O
Flooring Footwear
System
O
O
ESD STM 97.1
or
ESD STM 97.2
< 35 X 10
6
ohm
6
or
< 100 Volts
6
Protected Area
6.2.3
Work Surface
O
O
ESD S 4.1
< 1 X 10
9
ohm
ESD STM4.2
< 200 Volts
6
Wrist Strap Cord
O
O
ESD S 1.1
0.8 X 10
6
to
1.2 X 10
6
ohm
Footwear
O
O
ESD S 9.1
< 1 X 10
9
ohm
7
Flooring
O
O
ANSI ESD S 7.1
< 1 X 10
9
ohm
7
Seating
O
O
ESD STM
12.1
< 1 X 10
9
ohm
7
Ionization (other than
room systems)
O
O
ANSI EOS/ESD
S 3.1
< 50 Volts
Voltage Offset
6
Ionization (room
systems)
O
O
ANSI EOS/ESD
S 3.1
< 150 Volts
Voltage Offset
5
Shelving
O
O
ESD ADV
53.1
< 1 X 10
9
ohm
7
Mobile Equipment
O
O
< 1 X 10
9
ohm
6
Continuous Monitors
O
O
Manufacturer
Specification
N/A
5
The values in the Recommended Range are obtained by using the Test Method, Standard or Advisory
provided in this table. See paragraph 6.2 for further guidance regarding alternate test methods.
6
This is a proposed value that has not been substantiated by any standard.
7
This value differs from the value in current standards. There is work in progress to harmonize the value.