This provides access to the password submenu. The password facility provides
protected access to the submenus within the root menu. The level of password
protection works progressively down the menu.
This submenu is itself protected with a password. The message ENtEr, PASS will be
displayed before displaying the password template. This will be shown as four zeros
with the leading zero flashing. This may be edited as an ordinary numeric field. The
password should be entered. Pressing ENTER with the correct password takes the
user into the submenu shown above. An incorrect password displays ACCESS,
dEniEd before returning to the point of entry.
4.2.4.1.1 CodE ( Password code )
This entry allows the user to modify the password code. The current password is
shown as an editable numeric entry. Passwords are four digits long and can range
from 0000 to 9999.
default setting: 4000
4.2.4.1.2 LEvEL (Password start level )
The password level may be set up to start from any of the following levels.
SEtPt ( The passwords apply to all submenus )
INPUt ( Passwords start from in Input submenu )
OUtPUt ( Passwords start from the Output submenu )
SyS ( Passwords start from the System submenu )
CALIb ( Passwords apply to the Calibration submenu only )
default setting: CALIb
4.2.4.2 AUtOCy ( Automatic cycle )
Autocycle is a parameter which is used to control the way that the menu operation
SYSTEM MENU
PROGRAMMING
Page 61