OPERATION
PRODUCT SPECIFICATIONS:
CARBON MONOXIDE ALARM USER MANUAL
ELECTROCHEMICAL CARBON MONOXIDE ALARM GS811-A
STATUS indicator: The STATUS indicator (green LED) is used to indicate work status of the CO alarm.
ALARM indicator: The ALARM indicator (red LED) is used to indicate alarm or warning status of the CO alarm.
TEST/RESET button: The TEST/RESET button is used to test the unit's electronics and to reset the unit during alarm.
Press and hold 0.5 seconds then release to enable the TEST/RESET button.
Start up state: When first power on, 30 seconds before the green light flash every 3 seconds, This is preheated state,
30 seconds later the green light flashing every 30 seconds indicates the unit is functioning properly
Normal operation: The green LED flashes every 30 seconds. It indicates the CO alarm is unit is functioning properly.
Malfunction warning: The red LED flashes and the horn chirps once every 35 seconds. It indicates the CO alarm is in
malfunction condition. Replace battery, if condition continues, the CO alarm has malfunctioned. Replace immediately.
The malfunction alarm will not respond CO.
Low battery voltage warning: The red LED flashes and the horn also chirps twice every 35 seconds. It indicates the
battery is low. You need to replace the battery
NOTE: The detector will not protect against the risk of carbon monoxide poisoning when the battery has drained.
End of life warning: The red LED flashes and the horn chirps 3 times every 35 seconds. It indicates end of life of CO
alarm. You need to replace the CO alarm immediately.
WARNING: After Seven(7) years from initial power up, the alarm will under the end of life warning model.
Power:
GS811-A