ARC1 Mini Mullion reader
MA1 OEM Module
Installation instructions
Lecteur Etroit ARC1
Module OEM MA1
Notice d’installation
Lector Estrecho ARC1
Módulo OEM MA1
Procedimiento de instalación
conforme con
NOM-024 -SCFI-2013
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A10- Page 1 sur 6 - Ed. 06/04/2022
STid reserves the right to make change without notice, for the purpose of product improvement.
Product references
Outputs cable: 3 m
A B
Output cable
Type
Wiegand
Clock & Data
RS485
Brown
0 Vdc
Red
+Vcc (+9 Vdc to +15 Vdc)
Grey
D0
Code
NC
Blue
D1
Data
L+
Yellow
Clock
Clock
L -
Green
Led 1
Orange
Led 2
White
Buzzer
Power supply characteristics
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply: Range: +9 Vdc to +15 Vdc Typical: 12 Vdc
Max. consumption at 12 Vdc:
ARC1-XY: 130 mA
ARC1S-XY /PH5: 140 mA
ARC1S-XY /BT1: 150 mA
MA1-XY: 130 mA
MA1S-XY /PH5: 140 mA
MA1S-XY /BT1: 150 mA
Characteristics
Communication: RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connector output: - 8 female stamped crimp terminals 28-22AWG (Wurth Electronik 62400113722DEC)
- 8 points female dual-row terminal housing (Wurth Electronik 624008213322)
(use Crimp Hand Tool
WURTH ELEKTRONIK
600624228220)
Cable output: TRANXALARM - 8x0,22mm
2
Length 3.05m
Protection: IP65 classified reader
Buzzer / LED
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
respectively on the
Led 1
”, “
Led 2
” and “
Buzzer
inputs of the reader’s connector or controlled by the communication protocol of the reader (SSCP
®
/ OSDP
TM
).
Anti-tearing
Tearing is detected by an accelerometer. When the reader is wrenched:
for R/S 31: the wrenching signal will be emitted on the “Data/Data1” line. This function is configurable via a configuration card.
for R/S 33 and OSDP
TM
: the reader will perform the operations configured with the configuration card.
for W33: the reader will perform the operations configured with the SSCP
®
protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Read-only reader configuration
R and S readers are configurable with SCB RFID / Virtual configuration card.
OSDP
TM
readers are configurable with OCB RFID / Virtual configuration card or with FileTransfer command.
If the SCB/OCB is compatible with the reader’s firmware, the LED lights green and the buzzer beeps five times.
If the SCB/OCB is not compatible with the reader’s firmware, the LED lights red and the buzzer is activated for 1 s.
If the SCB/OCB key is different from the reader’s key: no reaction.
Caution: set your reader with your own company key.
Powering-up the readers
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only readers and OSDP
TM
readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4. For Bluetooth
®
reader only: Activating white fixed LED during Bluetooth initialization.
5. Activation of the default LED (read-only: flashes blue, OSDP
TM
: off; if no customer specific configuration).
Caution for Bluetooth reader
Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand in front
of the reader…).
TBLOCK option
Connection
- Press the orange part to open.
- Insert the wire.
- Release the orange part.
- Check that the wire is correctly clipped.
Precautions for installation
The supply voltage at the reader’s connector should be between +9 Vdc and +15 Vdc.
As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and
the proximity of the reader.
Recommended distance between two readers: parallel plane: 15.8 in same plane: 15.8 in perpendicular plane: 11.8 in.
Recommended distance between two Bluetooth
®
readers: 2 meters / 78.74 inch either plan.
Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
Use a ferrite (two-way) for the cable (power supply and data).
Example: reference 74271222 WURTH ELEKTRONIK
.
By design, the reader can be installed indoors and outdoors.
BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
Operating temperature: -4 °F to 158 °F / -20°C à +70°C.
ARC1-XY
ARC1S-XY/PH5
ARC1S-XY/BT1
MA1-XY
MA1S-XY/PH5
MA1S-XY/BT1
X:
1: TTL Output
3: RS485 Output
Y:
A: cable
B: cable with connector
Reader
Host
0.94 in
1.34 in
US
FR
ES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stid ARC1-XY and is the answer not in the manual?

Stid ARC1-XY Specifications

General IconGeneral
BrandStid
ModelARC1-XY
CategoryControl Unit
LanguageEnglish