INSTALLATION
Installation
www.stiebel-eltron.com DHB STi | 23
ENGLISH
10. Installation
Standard installation
- Electrical connection from below on unfinished walls
- Water connection on unfinished walls
For further installation options, see chapter "Installation/
Installation options":
- Electrical connection from above on unfinished walls
- Electrical connection on finished walls
- Large conductor cross-section for electrical connection from
below
- Connecting a load shedding relay
- Water installation on finished walls
- Water installation on finished walls with brazing/ compres-
sion fitting
- Water installation on finished walls; fitting the appliance
cover
- Installation of lower back panel with threaded fittings on fin-
ished walls
- Wall mounting bracket when replacing an appliance
- Installation with offset tiles
- Pivoting appliance cover
10.1 Standard installation
Opening the appliance
26�02�02�0864
Open the appliance by pulling the flap downwards, undo the
screw and lift up the appliance cover.
26�02�02�1101
Remove the back panel by pressing the two locking hooks
and pulling the lower section of the back panel forwards.
Preparing the power cable
160
30
1
26�02�02�0824�
1 Installation aid
Prepare the power cable.
Fitting the wall mounting bracket
26�02�02�0810�
Mark out the holes for drilling using the installation plate.
If the appliance is to be installed with water connections on
finished walls, also mark out a fixing hole in the lower part
of the template.
Drill the holes and secure the wall mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Fit the wall mounting bracket.
Making the water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
12
D0000053319
Seal and insert the twin connectors.