Installation
10.3 Installation options
- Electrical connection from above on unfinished walls
- Electrical connection on finished walls
- Large conductor cross-section for electrical connection from
below
- Water installation on unfinished walls
- Wall mounting bracket when replacing an appliance
- Installation with offset tiles
- Pivoting appliance cover
- Operation with preheated water
Electrical connection from above on unfinished walls
26�02�02�1123�
Cut open the cable grommet for the power cable.
Push down the locking hook for securing the mains terminal.
Pull out the mains terminal.
Reposition the mains terminal in the appliance from the
bottom to the top and secure the mains terminal by sliding it
under the locking hook.
Route the control wires under the wire guide.
Electrical connection on finished walls
!
Material losses
If you cut open the wrong knock-out in the appliance
cover by mistake, you must use a new appliance cover.
Cut or break out the required entries in the back panel and
appliance cover cleanly (for positions, see chapter "Specifica-
tion/ Dimensions and connections"). If necessary, use a file.
Route the power cable through the cable grommet. Connect
the power cable to the mains terminal.
Note
This type of connection changes the IP rating of the ap-
pliance.
Change the type plate. Cross out "IP 25" and mark
the box "IP 24". Use a ballpoint pen to do this.
Large conductor cross-section for electrical connection from
below
If you use cables with a large cross-section, you can fit the cable
grommet after the appliance has been installed.
1.
3.
4.
2.
26�02�02�1124�
Before installing the appliance, use a screwdriver to push out
the cable grommet.
Slide the cable grommet over the power cable. For this, use
the installation aid. If the cross-section is >6mm², enlarge
the hole in the cable grommet.
Push the cable grommet into the back panel.
Water installation on unfinished walls
12
D0000053319
Seal and screw in the twin connectors (not included in stand-
ard delivery).
D0000041724
2
3
1
3
1 Tee for cold water
2 Tee for domestic hot water
3 Cap
Fit the water connections.
D0000043291
Fit the strainer and the plastic profile washer in the tee for
the cold water inlet.