OPERATION
Menu structure
22 | LWZ304-404 SOL  www.stiebel-eltron.com
Menu item/parameter Options Direct Unit Dis-
play 
only
Min. Max. Standard
LWZ 304 SOL 
[  L W Z 4 0 4 S O L  ]
Energy sav-
ing recom-
mendation
System 
value
 FLOW PROPORTION HC1 19 0 100 30
 MAX. SET VALUE HC1 °C 10 65 50
 MIN. SET VALUE HC1 °C 0 40 10
 HEATING CURVE HC1 X
 HEATING CURVE HC2
 GRADIENT HC2
16
0
5
0.4
0.2 for under-
floor heating
system
 LOW END HC2 17 °C 0 20 3 5
 ROOM INFLUENCE HC2 18 0 100 0
 MAX. SET VALUE HC2 °C 10 65 45
 MIN. SET VALUE HC2 °C 0 40 10
 HEATING CURVE HC2 X
 STANDARD SETTING
 INTEGRAL COMPONENT Kmin 1 999 100
 MAX BOOSTER STG HTG 31 0 3 3
 MAX FLOW TEMP HTG. °C 10 75 55
 SUMMER MODE 49 °C 10 25 17 13
 HYST. SUMMER MODE 50 K 1 7 4 3
 OUTSIDE T ADJUSTMENT 77 h 0 24 1
 DUAL-MODE POINT 78 °C -10 10 -2
 BOOSTER TIMEOUT 79 min 0 60 20 40
 OUTSIDE T CORRECTION 86 °C -20 30 0
 SUPPR TEMP MEAS 58 s 0 120 60 120
 HYSTERESES
 HYSTERESIS 1 P21 K 0 10 4
 HYSTERESIS 2 P22 K 0 10 3
 HYSTERESIS 3 P23 K 0 5 3
 HYSTERESIS 4 P24 K 0 5 2
 HYSTERESIS 5 P25 K 0 5 2
 ASSYMMETRY OF HYST. P29 1 5 2
DHW
 DHW TEMPERATURES
 DHW SET DAY 04 °C 10 65 45
 DHW SET NIGHT 05 °C 10 65 45
 DHW SET STANDBY 06 °C 10 65 10
 DHW SET MANUAL 11 °C 10 65 45
 DHW TEMPERATURE °C X - - -
 STANDARD SETTING
 HYSTERESIS 32 K 2 10 2
 BOOSTER TIMEOUT 33 min 0 360 90
 BOOSTER T ACTIVATE 34 °C -20 10 -10
 PASTEURISATION 35 d 1 30 30
 MAX DHW HTG DUR. 36 h 6 12 12
 PASTEURISATION TEMP. °C 10 65 10
 PASTEURISATION TIME 00:00 23:45 02:00
 DHW BOOSTER STAGE 0 3 3
 DHW BUFFER MODE OFF| ON 84 OFF ON OFF
 MAX FLOW TEMP DHW °C 10 75 75
 DHW ECO OFF| ON 89 OFF ON ON
VENTILATION
 VENTILATION STAGES
 DAY STAGE 07 0 3 2 ( Delivered
condition: 0 )
 NIGHT STAGE 08 0 3 1 ( Delivered
condition: 0 )
 STANDBY STAGE 09 0 3 0 ( Delivered
condition: 0 )
 PARTY STAGE 0 3 3 ( Delivered
condition: 0 )
 MANUAL STAGE 12 0 3 2 ( Delivered
condition: 0 )
 TIME
 UNSCHED. VENT TIME STAGE 0 46 min 0 1000 60