Fault: Motor does not start
Fault: Poor suction performance
Fault: No suction performance when
wet-vacuuming
Troubleshooting
Cause Remedy
Mains circuit-
breaker has been
tripped
Check and reset
mains circuit
breaker
Overload protection
has been tripped
Let vacuum
cleaner cool for
approx. 5 minutes
Cause Remedy
Filter bag is full See "Emptying the
container"
Suction hose / tool
is clogged
Clean suction
hose / tool
Filter element is
fouled
See "Cleaning the
filter element" and
"Replacing the fil
-
ter element"
Gasket between
upper part of vac
-
uum cleaner and
container is fouled
or faulty
Clean or replace
gasket
Cause Remedy
Container full
(intake port is
sealed by float)
See "Emptying the
container"