SODISE NIU 10434 V.2.2
SODISE 85 Route de Pont Gwin 29510 Briec
FRANCE 12
10. Replace the head block and the two screws
4.2. Cleaning
Make sure that the surface of the appliance is clean (no sand, dirt or grease). Use soapy water or non-
toxic solvents.
Do not use petroleum-based solvents.
Make sure that the vent holes are not blocked.
5. Problems – Solutions
The end of the wick turns blue
Decrease the sharpening
pressure and time
Allow the wick to cool in water
between one sharpening and
the other
One edge is longer than the
other
Sharpen the shorter side a little
longer Sharpen both sides for
the same time and applying the
same pressure.
Sharpen the shorter side a little
longer.
Sharpen both sides at the same
time and using the same
pressure.
The engine is running but the
wheel is not running
The inner walls of the control
cylinder (3) are flush with the
outer walls of pin (12)
Level them as described in the
chapter "Maintenance,
replacing the grinding wheel".
The engine is not running
Contact a qualified technician