Art. 420
Geyser Nebulizer Mini 2 L Li-Ion
Art. 420
Geyser Nebulizer Mini 2 L Li-Ion
For further information about the product, please contact info@stockergarden.com.
Where to store the nebulizer
1. Ensure that the battery is fully charged.
2. Make sure that the switch is off.
3. Store the sprayer in a cool and dry environment with room temperature from 15 to 35 C.
4. If the device will not be used for a long time, make sure to charge the battery at least once
every six months.
5. The sprayer and the USB cable must be placed in a secure location, protected from heat,
dust and moisture.
6. The sprayer and flammable matter must be kept at least 1.5 meters apart.
7. Do not turn on the power switch while storing.
Storage
The most important thing to keep in mind before storing your sprayer’s lithium ion battery, is to
make sure that the battery is fully charged up and the power switch is off.
Troubleshooting
Please contact your local retailer or Stocker S.r.l. for assistance and service
Problem Cause Solution
The nebulizer does not
spray even if the motor
is running
1. The filter is clogged
2. Faulty motor
3. The delivery tube
between the tank and
motor is crushed
1. Remove the head from the tank
and rinse it thoroughly
2./3. Send it for repair to an
authorized local retailer or to
Stocker Srl
The motor does not run
even with the nebulizer
switched on (The LED on
the power button is on)
1. Some wires have come
loose
2. Faulty motor
3. The pressure is too
high or too low
4. The tank is empty
1./2. Send it for repair to an
authorized local retailer or to
Stocker Srl
3. Check the correct assembly of
the nozzles.
4. Fill the tank
The nebulizer does not
start (the LED above the
start key is off)
1. Low battery
2. Battery fault
3. Power button fault
1. Charge the battery
2. Replace the battery
3. Send to repair service center by
local authorized reseller or Stocker
Srl
Cleaning and maintenance
The nebulizer must be cleaned after each cycle to prevent the liquids used from causing
corrosion and blocking of the nozzles.