Data badge
Front frame
Type of gas
This appliance must only be used with
Natural Gas.
Gas category
Natural Gas - I2H, G20 @ 20mbar
Pressure setting
20 mbar
Pressure test point - use oven injector
Ignition
2 outlet re-ignition generator
Appliance class
Class 3, Built-In Oven & Grill
Light bulbs
2 grill & 2 oven 4 x 25W
Electrical supply
230 - 240V ~ 50Hz
Grill
• Burner - Bray surface combustion
type
• Spark gaps 3 - 4mm
• Nominal Rate Qn 2.25kW
• Injector (Copreci) 1.12mm
Oven
• Burner - Bray type burner, sheet
steel body, stainless steel flame strip
• Nominal Rate Qn 2.5kW
• Injector 1.15mm
Total Heat Input
∑Qn 4.75kW
Countries of destination
GB - Great Britain, IE - Ireland
40
TECHNICAL DATA