Data Badge
Front Frame
Gas Category
This appliance is for use on either
Natural Gas only or LP Gas only. This
is clearly marked on the data badge.
Natural Gas - I
2H, LP Gas - I3+
Pressure Test Point
Top of inlet block
Pressure Setting
G20 Natural Gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Ignition
Automatic Spark
Oven / Grill Light(s)
4 x 25W (2 in each oven)
Electrical supply
230 - 240V ~ 50Hz
Grill
Burner: Surface combustion behind
ceramic glass. Spark Gap: 3 - 4mm.
Top Oven
Burner: Rotary surface combustion.
Main Oven
Burner: Rotary surface combustion.
Appliance class
Class 1, freestanding appliance
Countries of Destination
GB - Great Britain, IE - Ireland
31
Gas Burner Nominal Grammes per hour Injector
Rate Qn Propane Butane size
Natural Grill 3.2kW - - Amal Size 230
Gas Top Oven 1.85kW - - Amal Size 130
Main Oven 2.5kW - - Amal Size 180
Total heat input ∑Qn 5.7kW - - -
LP Gas Grill 3.2kW 229 g/h 233 g/h Amal Size 95
Top Oven 1.8kW 129 g/h 131 g/h Amal Size 55
Main Oven 2.3kW 164 g/h 167 g/h Amal Size 75
Total heat input ∑Qn 5.5kW 393 g/h 400 g/h -
TECHNICAL DATA